10/100/1000TX to 1000X SFP Industrial Media Converter – Signamax is designed to provide reliable performance and dependable operation for professional installations, network infrastructure, telecommunications, audio/video, or equipment support applications. Built for durability and compatibility, this product helps simplify deployment while delivering the quality and functionality required for commercial, industrial, and enterprise environments.

SKU: FO-065-1896SFPTB Categories: , , Vendor: signamax
Description
  • APPLICABLE STANDARDS

IEEE 802.3 10BaseT
IEEE 802.3u 100BaseTX
IEEE 802.3ab 1000BaseT
IEEE 802.3z 1000BaseSX/LX
SFP Multi-Source Agreement (MSA)

  • PORTS

1 – RJ-45 10/100/1000BaseT/TX Auto-Negotiation, Auto-MDI/MDIX port, plus
1 -1000Base SFP port.

  • LED STATUS INDICATORS

Per Unit: Power1, Power2, Power3 (Green). Fault, LFS
Per Port: 10/100/1000BaseT/TX port: Link/Activity, Speed, Full Duplex/Collision. 1000Base SFP port – Link/Activity

  • PERFORMANCE

Latency: <4.2 μs
Throughput, per port: @ 1000BaseT 1,488,100 pps; @ 100BaseTX: 148,810 pps; @ 10BaseT: 14,881 pps (64-byte packets)

  • ELECTRICAL CHARACTERISTICS

DC Input Range: 12 to 48 V DC Connected via Redundant Terminal Block

  • ENVIRONMENTAL REQUIREMENTS

Operating Temperature: -40°F to 167°F (-40°C to 75°C)
Storage Temperature: -40°F to 185°F (-40°C to 85°C)
Operating Humidity: 5% to 95% (non-condensing)

  • PHYSICAL CHARACTERISTICS

Dimensions: 1.97 W” x 4.33” D x 5.31” H (50 mm x 110 mm x 135 mm)
Housing: IP30 protection, metal case. Pre-attached DIN-rail included.
Weight: 1.76 lb (0.8 kg)

  • CERTIFICATIONS

NEMA TS1/2 Environmental requirements for traffic control equipment
Safety: UL 508
EMI: FCC; EN61000-6-3
EMS: ESD Standards (EN61000-4-2); Radiated RFI Standards (IEC 61000-4-3); Burst Standards (IEC 61000-4-4); Surge Standards (IEC 61000-4-5); Induced RFI
Standards (IEC 61000-4-6); Magnetic Field Standards (IEC 61000-4-8); Voltage Dip Standards (IEC 61000-4-11)
Environmental Test Compliance: Vibration Resistance (IEC 60068-2-6 Fc); Operation/Storage/Transport Shock (IEC 60068-2-27 Ea); Free Fall (IEC 60068-2-32 Ed)

  • WARRANTY