ZV 2 4-3-225 – T-Splitter, Sensor/Actuator, double M12 3 pole female, with Black PUR cable

Call for Price

Compare

Description

Safety & Environmental Compliance

RoHS Compliant: Yes

Resistances

Halogenfree: Yes
Oil Resistance: Yes

Notes

Note Derating: Notice derating
Variants
Item # Item Description Cable Length
23368 ZV 2 4-3-225/15 M 15 m
43780 ZV 2 4-3-225/10 M 10 m
43782 ZV 2 4-3-225/2 M 2 m
43783 ZV 2 4-3-225/5 M 5 m

Product Description

Product Family: Sensor / Actuator Connectors
Brand: Lumberg Automation
Connector Type: T-Splitter
Shielding: Unshielded
Rated Voltage: 63 V
Rated Impulse Voltage: 1.5 kV
Operating Voltage: 50 V AC / 60 V DC
Rated Current*: 4 A

Technical Data Side 1

Product Sub Family: M12 Standard
Type of Contact / Gender: 2 x Female
Connector Design: T Body
Attachment Type: Coupling Nut
Number of Pins: 4
Coding: A
Contact Resistance: ? 5 mOhm
Insulation Resistance: ? 10^9 Ohm
Mating Cycles: ? 100
Ambient Temperature (Operation)*: – 25 °C – + 80 °C
Protection Degree / IP Rating**: IP65, IP67
Design Standard: IEC 61076-2-101
Pollution Degree: 3 acc. to DIN EN 60664-1 (VDE 0110-1)
Overvoltage Category: III acc. to DIN EN 60664-1 (VDE 0110-1)
Contact Base Material: CuSn
Contact Plating: Cu/Au
Contact Bearer Material: TPU
Contact Bearer Color: Black
Flammability Class (Contact Bearer): UL 94 HB
Molded Body Material: TPU
Molded Body Color: Orange
Flammability Class (Molded Body): UL 94 HB
Attachment Material: CuZn
Attachment Plating: 1xNickel-plated, 1xNylon Black coated
O-Ring Material: FKM, green
Fastening Torque (Attachment): M 12×1: (50-60) Ncm, hand-tight

Cable Data

Cable Number: 225
Conductor Size: 0.34 mm²
Number of Wires: 4
Minimal Bending Radius (Fixed Inst): 5 x D
Minimal Bending Radius (Flexible Inst): 10 x D
Cycles (Bending): 5 M
Cycles (Torsion): ? 3 M @ ± 360 °/1 m
Conductor material: Cu
Cable Jacket Material: PUR
Cable Jacket Color: black matt similarly RAL 9005
Cable Diameter D: ø 4.70 ± 0.15 mm
Wire Insulation Material: PP
Insulated Wire Diameter: ø 1.30 ± 0.15 mm
Ambient Temperature (Fixed Installation): – 50 °C – + 90 °C (UL: + 80 °C)
Ambient Temperature (Flex Installation): – 25 °C – + 90 °C (UL: + 80 °C)
Ambient Temperature (Drag Chain Inst): – 25 °C – + 60 °C
UL Cable Type: AWM: 20549
Flammability Class (Cable Jacket): DIN EN 60332-2-2, VDE 0482-332-2-2, IEC 60332-2-2, CSA FT-2
Cable Characteristics: Good microbes and hydrolysis resistance; Mainly plasticizer diffusion free; Exclusion of PVC and silicone; Coldness flexibility; Free of lacquer wetting disturbing substances