Description
Product Overview
| Suitable Applications: | Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, …),low voltage digital control (24v, ), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners |
Physical Characteristics (Overall)
Conductor
| Element | AWG | Stranding | Material | Nominal Diameter | No. of Pairs |
|---|---|---|---|---|---|
| Pair(s) | 16 | Solid | Chromel & Alumel | 0.051 in | 8 |
| Conductor Count: | 16 |
Insulation
| Element | Material | Nominal Diameter | Nominal Wall Thickness |
|---|---|---|---|
| Pair(s) | XLP, XLPO, XLPE (Thermoset) | 0.113 in | 0.031 in |
Color Chart
| Number | Color |
|---|---|
| Pair 1 | Yellow and Red Numbered 1 |
| Pair 2 | Yellow and Red Numbered 2 |
| Pair 3 | Yellow and Red Numbered 3 |
| Pair 4 | Yellow and Red Numbered 4 |
| Pair 5 | Yellow and Red Numbered 5 |
| Pair 6 | Yellow and Red Numbered 6 |
| Pair 7 | Yellow and Red Numbered 7 |
| Pair 8 | Yellow and Red Numbered 8 |
Inner Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG |
|---|---|---|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC – Tinned Copper | 0.046 in | 18 |
Outer Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG |
|---|---|---|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC – Tinned Copper | 0.046 in | 18 |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 0.824 in | 0.063 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR |
|---|
| 4.2 Ohm/1000ft |
Temperature Range
| UL Temp Rating: | 90°C Wet/Dry |
| Operating Temperature Range: | -25°C To +90°C |
Mechanical Characteristics
| Bulk Cable Weight: | 211 lbs/1000ft |
| Max. Pull Tension: | 499 lbs |
| Min Bend Radius (Overall): | 6.5 in |
Standards
| NEC/(UL) Compliance: | TC |
| ANSI Compliance: | MC 96.1-1982 Type KX |
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2011/65/EU (RoHS 2): | Yes |
| EU Directive 2012/19/EU (WEEE): | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment): | Yes |
| EU Directive Compliance: | EU Directive 2003/11/EC (BFR) |
| EU CE Mark: | Yes |
| CA Prop 65: | Yes |
Suitability
| Suitability – Indoor: | Yes |
| Suitability – Outdoor: | Yes |
| Suitability – Sunlight Resistance: | Yes |
Flammability, LS0H, Toxicity Testing
| CSA/C(UL) Flammability: | FT4 |
| IEEE Flammability: | 1202 |
| UL voltage rating: | 600 V RMS (Type TC) |
History
| Update and Revision: | Revision Number: 0.53 Revision Date: 01-10-2024 |