U12142 – TC-ER XLPE/LSZH, 12 C #14 Str BC, XLPE Ins E2, Blk LSZH Jkt, 600V TC-ER 90C Dry/Wet SUN RES

Call for Price

Description

Product Overview

Suitable Applications: harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Physical Characteristics (Overall)

Conductor
Element AWG Stranding Material No. of Conductors
Conductor(s) 14 7×22 BC – Bare Copper 12
Conductor Count: 12
Insulation
Material Nominal Diameter Nominal Wall Thickness
XLP, XLPO, XLPE (Thermoset) 0.133 in 0.031 in
Color Chart
Number Color
1 Black
2 Red
3 Blue
4 Orange
5 Yellow
6 Brown
Conductors 7 – 11 Same as 2 -6 except with Black Stripe
Conductor 12 Black/Red
Outer Jacket
Material Nominal Diameter Nominal Wall Thickness
LSZH – Low Smoke Zero Halogen (Flame Retardant) 0.713 in 0.083 in

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR
2.52 Ohm/1000ft
Current
Max. Recommended Current [A]
12.5 Amps per Conductor at 30ºC
Voltage
UL Description UL Voltage Rating Voltage Rating [V]
TC 600 V RMS (Type TC) 600 V RMS (Type TC)

Temperature Range

UL Temp Rating: 90°C Dry, 90°C Wet
Operating Temperature Range: -30°C To +90°C
Wet Temp Range: -30°C To +90 °C

Mechanical Characteristics

Bulk Cable Weight: 336 lbs/1000ft
Max. Pull Tension: 386 lbs
Min. Bend Radius/Minor Axis: 2.85 in

Standards

NEC/(UL) Compliance: TC-ER, XHHW-2

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/11/EC (BFR): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: Yes

Suitability

Suitability – Indoor: Yes
Suitability – Outdoor: Yes
Suitability – Sunlight Resistance: Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: UL1685 UL Loading
IEEE Flammability: 1202
UL voltage rating: 600 V RMS (Type TC)

Related Part Numbers

Variants
Item # Put-Up Type
U12142 0105000 Reel

History

Update and Revision: Revision Number: 0.51 Revision Date: 01-10-2024
You were not leaving your cart just like that, right?

You were not leaving your cart just like that, right?

Enter your details below to save your shopping cart for later. And, who knows, maybe we will even send you a sweet discount code :)