Description
Product Overview
| Suitable Applications: | Applicable for fixed or moderate flexing wiring inside Railway Rolling Stock like High-Speed Trains (CRH, Shinkansen, ICE, TGV), Metro, locomotives, and trolley buses, etc |
Construction Details
Conductor
| Size | Stranding | Material |
|---|---|---|
| 0.5 mm² | 19×0.18 mm | TC – Tinned Copper |
Insulation
| Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes |
|---|---|---|---|---|
| XLP, XLPO, XLPE | 0.29 mm (0.011 in) | 1.42 mm (0.0559 in) | White#1, White#2, White#3, White#4, White#5, White#6, White#7, White#8 | D.C. stability on insulation at 300Vdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown |
| Table Notes: | D.C. stability on insulation at 300Vdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown |
Outer Shield
| Shield Type | Material | Coverage |
|---|---|---|
| Braid | Tinned Copper (TC) | 80% |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter |
|---|---|---|
| XLP, XLPO, XLPE | 0.87 mm (0.034 in) | 7.90 mm (0.311 in) |
| Overall Cable Diameter (Nominal): | 7.9 ± 0.20 mm |
Electrical Characteristics
Electricals
| Max. Conductor DCR |
|---|
| 40.1 Ohm/km (12.2 Ohm/1000ft) |
Voltage
| Breakdown Voltage |
|---|
| 2.5kVac/5min |
Mechanical Characteristics
Temperature
| Operating |
|---|
| -40°C to +120°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 79 mm (3.1 in) | 79 mm (3.1 in) |
| Bulk Cable Weight: | 93.3 kg/km (62.7 lbs/1000ft) |
Standards and Compliance
| Flammability / Reaction to Fire: | IEC 60332-1-2, IEC 60332-2-25 |
| ISO/IEC Compliance: | IEC 60228 |
| CENELEC Compliance: | EN 50306-4 |
| European Halogen Free Standards: | IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3 |
| Other Standard Compliance(s): | TJ/CL 313 |
Product Notes
| Notes: | EMEA PN: RTO4P05P; Table 7 Category MM, ROHS Compliant |
History
| Update and Revision: | Revision Number: 0.58 Revision Date: 11-27-2023 |