RTD2C2.5P – RailTuff™ Thin wall cable EN 50306-4 3P 300V 2 C 2.5 mm² Str TC, XLPO Ins, XLPO Outer Jkt

Call for Price

Compare

Description

Product Overview

Suitable Applications: Applicable for fixed or moderate flexing wiring inside Railway Rolling Stock like High-Speed Trains (CRH, Shinkansen, ICE, TGV), Metro,
locomotives, and trolley buses, etc

Construction Details

Conductor
Size Stranding Material
2.5 mm² 19×0.40 mm TC – Tinned Copper
Insulation
Material Nom. Insulation Diameter Color Code Notes
XLP, XLPO, XLPE 2.75 mm (0.108 in) White#1, White#2 D.C. stability on insulation at 300Vdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown
Table Notes: D.C. stability on insulation at 300Vdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown
Outer Shield
Shield Type Material Coverage
Braid Tinned Copper (TC) 80%
Outer Jacket
Material Nom. Thickness
XLP, XLPO, XLPE 0.56 mm (0.022 in)
Overall Cable Diameter (Nominal): 7.5 ± 0.20 mm

Electrical Characteristics

Electricals
Max. Conductor DCR
8.21 Ohm/km (2.50 Ohm/1000ft)
Voltage
Breakdown Voltage
2.5kVac/5min

Mechanical Characteristics

Temperature
Operating
-40°C to +120°C
Bend Radius
Stationary Min. Installation Min.
75 mm (3.0 in) 75 mm (3.0 in)
Bulk Cable Weight: 94 kg/km (63 lbs/1000ft)

Standards and Compliance

Flammability / Reaction to Fire: IEC 60332-1-2, IEC 60332-2-25
ISO/IEC Compliance: IEC 60228
CENELEC Compliance: EN 50306-4EN 45545-2
European Halogen Free Standards: IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3
Other Standard Compliance(s): TJ/CL 313

Product Notes

Notes: EMEA PN: RTD2C25P; Table 3 Category MM, ROHS Compliant

History

Update and Revision: Revision Number: 0.39 Revision Date: 02-15-2024