RTA1C1 – RailTuff™ Thin wall cable 300V 1 C 1.0 mm² Str TC, XLPO Ins

Call for Price

Compare

Description

Product Overview

Suitable Applications: Applicable for fixed or moderate flexing wiring inside Railway Rolling Stock like High-Speed Trains (CRH, Shinkansen, ICE, TGV), Metro, locomotives, and trolley buses, etc

Construction Details

Conductor
Size Stranding Material
1 mm² 37×0.18 mm TC – Tinned Copper
Insulation
Material Nom. Thickness Nom. Insulation Diameter Color Code
XLP, XLPO, XLPE 0.34 mm (0.013 in) 1.77 mm (0.0697 in) White#1
Table Notes: D.C. stability at 300Vdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown
Overall Cable Diameter (Nominal): 2.25 ± 0.03 mm

Electrical Characteristics

Voltage
Breakdown Voltage
2.5kVac/5min

Mechanical Characteristics

Temperature
Operating
-40°C to +120°C
Bend Radius
Stationary Min. Installation Min.
9 mm (0.35 in) 7 mm (0.28 in)
Bulk Cable Weight: 10.6 kg/km (7.12 lbs/1000ft)

Standards and Compliance

Flammability / Reaction to Fire: IEC 60332-1-2, EN 50305
European Halogen Free Standards: IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3

History

Update and Revision: Revision Number: 0.27 Revision Date: 11-27-2023