Description
Product Overview
Suitable Applications: | Applicable for fixed or moderate flexing wiring inside Railway Rolling Stock like High-Speed Trains (CRH, Shinkansen, ICE, TGV), Metro, locomotives, and trolley buses, etc |
Construction Details
Conductor
Size | Stranding | Material |
---|---|---|
1 mm² | 37×0.18 mm | TC – Tinned Copper |
Insulation
Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|
XLP, XLPO, XLPE | 0.34 mm (0.013 in) | 1.77 mm (0.0697 in) | White#1 |
Table Notes: | D.C. stability at 300Vdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown |
Overall Cable Diameter (Nominal): | 2.25 ± 0.03 mm |
Electrical Characteristics
Voltage
Breakdown Voltage |
---|
2.5kVac/5min |
Mechanical Characteristics
Temperature
Operating |
---|
-40°C to +120°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
9 mm (0.35 in) | 7 mm (0.28 in) |
Bulk Cable Weight: | 10.6 kg/km (7.12 lbs/1000ft) |
Standards and Compliance
Flammability / Reaction to Fire: | IEC 60332-1-2, EN 50305 |
European Halogen Free Standards: | IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3 |
History
Update and Revision: | Revision Number: 0.27 Revision Date: 11-27-2023 |