Description
Product Overview
| Suitable Applications: | Applicable for fixed or moderate flexing wiring inside Railway Rolling Stock like High-Speed Trains (CRH, Shinkansen, ICE, TGV), Metro, locomotives, and trolley buses, etc |
Construction Details
Conductor
| Size | Stranding | Material |
|---|---|---|
| 0.75 mm² | 37×0.16 mm | TC – Tinned Copper |
Insulation
| Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|
| XLP, XLPO, XLPE | 0.27 mm (0.011 in) | 1.62 mm (0.0638 in) | White#1 |
| Table Notes: | D.C. stability at 300Vdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown |
| Overall Cable Diameter (Nominal): | 1.62 ± 0.03 mm |
Electrical Characteristics
Voltage
| Breakdown Voltage |
|---|
| 2.5kVac/5min |
Mechanical Characteristics
Temperature
| Operating |
|---|
| -40°C to +120°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 6 mm (0.24 in) | 5 mm (0.20 in) |
| Bulk Cable Weight: | 8.4 kg/km (5.6 lbs/1000ft) |
Standards and Compliance
| Flammability / Reaction to Fire: | IEC 60332-1-2, EN 50305 |
| European Halogen Free Standards: | IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3 |
History
| Update and Revision: | Revision Number: 0.26 Revision Date: 11-27-2023 |