RTA1C0.5 – RailTuff™ Thin wall cable 300V 1 C 0.5 mm² Str TC, XLPO Ins

Call for Price

Compare

Description

Product Overview

Suitable Applications: Applicable for fixed or moderate flexing wiring inside Railway Rolling Stock like High-Speed Trains (CRH, Shinkansen, ICE, TGV), Metro, locomotives, and trolley buses, etc

Construction Details

Conductor
Size Stranding Material
0.5 mm² 19×0.18 mm TC – Tinned Copper
Insulation
Material Nom. Thickness Nom. Insulation Diameter Color Code
XLP, XLPO, XLPE 0.29 mm (0.011 in) 1.42 mm (0.0559 in) White#1
Table Notes: D.C. stability at 300Vdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown
Overall Cable Diameter (Nominal): 1.42 ± 0.03 mm

Electrical Characteristics

Voltage
Breakdown Voltage
2.5kVac/5min

Mechanical Characteristics

Temperature
Operating
-40°C to +120°C
Bend Radius
Stationary Min. Installation Min.
6 mm (0.24 in) 4 mm (0.16 in)
Bulk Cable Weight: 5.8 kg/km (3.9 lbs/1000ft)

Standards and Compliance

Flammability / Reaction to Fire: IEC 60332-1-2, EN 50305
European Halogen Free Standards: IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3

History

Update and Revision: Revision Number: 0.24 Revision Date: 11-27-2023