Description
Product Overview
Suitable Applications: | Applicable for fixed or moderate flexing wiring inside Railway Rolling Stock like High-Speed Trains (CRH, Shinkansen, ICE, TGV), Metro, locomotives, and trolley buses, etc |
Construction Details
Conductor
Size | Stranding | Material |
---|---|---|
0.5 mm² | 19×0.18 mm | TC – Tinned Copper |
Insulation
Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|
XLP, XLPO, XLPE | 0.29 mm (0.011 in) | 1.42 mm (0.0559 in) | White#1 |
Table Notes: | D.C. stability at 300Vdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown |
Overall Cable Diameter (Nominal): | 1.42 ± 0.03 mm |
Electrical Characteristics
Voltage
Breakdown Voltage |
---|
2.5kVac/5min |
Mechanical Characteristics
Temperature
Operating |
---|
-40°C to +120°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
6 mm (0.24 in) | 4 mm (0.16 in) |
Bulk Cable Weight: | 5.8 kg/km (3.9 lbs/1000ft) |
Standards and Compliance
Flammability / Reaction to Fire: | IEC 60332-1-2, EN 50305 |
European Halogen Free Standards: | IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3 |
History
Update and Revision: | Revision Number: 0.24 Revision Date: 11-27-2023 |