RMG1C95 – RailTuff™ Medium wall cable 1800V 1 C 95 mm² Str TC,XLPO Ins

Call for Price

Compare
SKU: RMG1C95 Categories: , , ,

Description

Product Overview

Suitable Applications: Applicable for fixed or moderate flexing wiring inside Railway Rolling Stock like High-Speed Trains (CRH, Shinkansen, ICE, TGV), Metro, locomotives, and trolley buses, etc

Construction Details

Conductor
Element No. of Elements Size Stranding Stranding Class Material
Conductor(s) 1 95 mm² 427×0.50 mm Class 5 TC – Tinned Copper
Insulation
Element Material Nom. Thickness Color Code
Conductor(s) XLP, XLPO, XLPE 2.2 mm (0.087 in) White, Black
Overall Cable Diameter (Nominal): 17.8 ± 0.40 mm

Electrical Characteristics

Electricals
Max. Conductor DCR
0.21 Ohm/km (0.064 Ohm/1000ft)
Table Notes: D.C. stability at 4.5kVdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown
Voltage
Voltage Rating Breakdown Voltage
1800/3000V 6.5kVac/5min
Table Notes: Dielectric strength on core in water for 1 hour (kVac): ? 10

Mechanical Characteristics

Temperature
Operating
-40°C to +90°C
Bend Radius
Stationary Min. Installation Min.
89 mm (3.5 in) 71 mm (2.8 in)
Table Notes: Elongation test at -40?:Elongation at break ? 30 %
Bulk Cable Weight: 933 kg/km (627 lbs/1000ft)

Standards and Compliance

Flammability / Reaction to Fire: IEC 60332-1-2, IEC 60332-3-24
ISO/IEC Compliance: IEC 60228, IEC 61034-2 – Smoke Density Min Transmittance = 70
CENELEC Compliance: EN 50264-3-1EN 45545-2
European Halogen Free Standards: IEC 60754-1 – Halogen Amount = HCI+HBr ? 0.5%, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3
Other Standard Compliance(s): TJ/CL 313

Product Notes

Notes: EMEA PN: RMG1C95;

History

Update and Revision: Revision Number: 0.24 Revision Date: 11-27-2023