Product Overview
Suitable Applications: |
In-building wireless systems for active and passive distributed antenna systems (DAS).
4G LTE, LTE Advanced (LTE-A) and LTE Advanced Pro with Licensed Assisted Access (LAA).
Public safety emergency responder radio communications systems (ERRCS).
CBRS/private LTE networks |
Physical Characteristics (Overall)
AWG |
Stranding |
Material |
Nominal Diameter |
No. of Coax |
5 |
Solid |
BCCA – Bare Copper Covered Aluminum |
0.188 in |
1 |
Material |
PE – Polyethylene (Semi-Solid) |
Material |
Coverage [%] |
Bare Copper (BC) |
100% |
Material |
Nominal Diameter |
PVC – Polyvinyl Chloride |
0.630 in |
Electrical Characteristics
Nominal Conductor DCR |
Outer Conductor DCR |
0.5 Ohm/1000ft |
0.9 Ohm/1000ft |
Nom. Capacitance Conductor to Shield |
23 pF/ft |
Nominal Characteristic Impedance |
50 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] |
Nom. Insertion Loss |
5 MHz |
0.35 dB/100ft |
30 MHz |
0.36 dB/100ft |
100 MHz |
0.66 dB/100ft |
150 MHz |
0.82 dB/100ft |
450 MHz |
1.47 dB/100ft |
700 MHz |
1.84 dB/100ft |
824 MHz |
2.03 dB/100ft |
890 MHz |
2.10 dB/100ft |
894 MHz |
2.12 dB/100ft |
960 MHz |
2.21 dB/100ft |
1000 MHz |
2.24 dB/100ft |
1700 MHz |
3.06 dB/100ft |
1800 MHz |
3.16 dB/100ft |
2000 MHz |
3.36 dB/100ft |
2300 MHz |
3.63 dB/100ft |
2400 MHz |
3.76 dB/100ft |
2700 MHz |
4.00 dB/100ft |
3000 MHz |
4.32 dB/100ft |
3400 MHz |
4.62 dB/100ft |
3500 MHz |
4.71 dB/100ft |
4000 MHz |
5.11 dB/100ft |
5000 MHz |
6.00 dB/100ft |
6000 MHz |
6.78 dB/100ft |
Nominal Delay |
Nominal Velocity of Propagation (VP) [%] |
1.15 ns/ft |
88% |
Frequency [MHz] |
Max. Power Rating [W] |
30 MHz |
6,190 W |
150 MHz |
2,740 W |
700 MHz |
1,240 W |
890 MHz |
1,100 W |
960 MHz |
1,050 W |
1,000 MHz |
1,030 W |
1,800 MHz |
760 W |
2,000 MHz |
720 W |
3,000 MHz |
580 W |
4,000 MHz |
490 W |
5,000 MHz |
440 W |
6,000 MHz |
390 W |
Non-UL Voltage Rating |
4000 VDC |
Frequency [MHz] |
Max. VSWR |
700-894 MHz |
1.25 |
806-960 MHz |
1.25 |
1700-2700 MHz |
1.25 |
2700-3555 MHz |
1.3 |
3700-4200 MHz |
1.35 |
Temperature Range
Operating Temperature Range: |
-20°C to +75°C |
Mechanical Characteristics
Bulk Cable Weight: |
162 lbs/1000ft |
Max. Pull Tension: |
249 lbs |
Min. Bend Radius/Minor Axis: |
4.92 in |
Applicable Environmental and Other Programs
Environmental Space: |
Indoor – Plenum |
Suitability
Suitability – Hazardous Locations: |
No |
Suitability – Indoor: |
Yes |
Suitability – Outdoor: |
No |
Plenum/Non-Plenum
Related Part Numbers
Non-Plenum Number: |
RA500, RA500R |
Item # |
Color |
Put-Up Type |
Length |
RA500P 0101000 |
Black |
Reel |
1,000 ft |
RA500P 0103000 |
Black |
Reel |
3,000 ft |
RA500P 0061000 |
Blue, Light |
Reel |
1,000 ft |
RA500P 0063000 |
Blue, Light |
Reel |
3,000 ft |
RA500P 3651000 |
White |
Reel |
1,000 ft |
RA500P 3653000 |
White |
Reel |
3,000 ft |
History
Update and Revision: |
Revision Number: 0.111 Revision Date: 12-22-2023 |