Description
Product Overview
| Suitable Applications: | Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas |
Construction Details
| RG Type: | 11 |
Conductor
| No. of Elements | Size | Stranding | Nom. Diameter | Material |
|---|---|---|---|---|
| 1 | 15 AWG | Solid | 1.55 mm | BC – Bare Copper |
Insulation
| Element | Material | Nom. Insulation Diameter |
|---|---|---|
| Insulated Conductor | PE – Polyethylene (Foam) | 7.25 mm (0.285 in) |
| Table Notes: | Centricity min. 85% |
Outer Shield
| Layer | Outer Shield Type | Material | Coverage |
|---|---|---|---|
| 1 | Tape | Tri-Laminate (Alum+Poly+Alum) | 100% |
| 2 | Braid | Tinned Copper (TC) | 45% |
Outer Jacket
| Material | Nom. Diameter |
|---|---|
| PVC – Polyvinyl Chloride | 10.1 mm |
| Table Notes: | According to EN 50290-2-20 |
Electrical Characteristics
| Regularity of Impedance: | Min. 46 dB |
Return Loss (RL)
| Frequency | Min. Return Loss |
|---|---|
| 5 – 30 MHz | 26 dB |
| 30 – 470 MHz | 26 dB |
| 470 – 1000 MHz | 23 dB |
| 1000 – 2000 MHz | 18 dB |
| Table Notes: | In each frequency band, 3 peak values up to 4 dB lower are allowed |
Attenuation
| Frequency | Nom. Attenuation |
|---|---|
| 5 MHz | 0.9 dB/100m |
| 50 MHz | 2.9 dB/100m |
| 100 MHz | 4.1 dB/100m |
| 200 MHz | 5.9 dB/100m |
| 400 MHz | 8.6 dB/100m |
| 600 MHz | 10.7 dB/100m |
| 800 MHz | 12.5 dB/100m |
| 1000 MHz | 14.2 dB/100m |
| 1350 MHz | 16.8 dB/100m |
| 1600 MHz | 18.5 dB/100m |
| 1750 MHz | 19.5 dB/100m |
| 2150 MHz | 21.9 dB/100m |
| 2400 MHz | 23.4 dB/100m |
| 3000 MHz | 26.7 dB/100m |
| Table Notes: | Max. attenuation 10% higher |
Electricals
| Max. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance Cond-to-Shield |
Nom. Characteristic Impedance | Nom. Velocity of Prop. |
|---|---|---|---|---|
| 9.4 Ohm/km (2.9 Ohm/1000ft) | 12.8 Ohm/km (3.90 Ohm/1000ft) | 55 pF/m (17 pF/ft) | 75 Ohm | 81% |
Screening
| Frequency | Min. Screening Attenuation |
|---|---|
| 30 – 1000 MHz | 85 dB |
Mechanical Characteristics
Temperature
| Operating | Installation | Storage |
|---|---|---|
| -15°C To +70°C | -5°C To +50°C | -15°C To +70°C |
Bend Radius
| Stationary Min. |
|---|
| 50 mm (2.0 in) |
| Bulk Cable Weight: | 95 kg/km |
Standards and Compliance
| Environmental Suitability: | Indoor – Euroclass Eca |
| Flammability / Reaction to Fire: | IEC 60332-1-2 |
| CPR Compliance: | CPR Euroclass: Eca |
| ISO/IEC Compliance: | IEC 61196 |
| CENELEC Compliance: | EN 50117-1 |
| European Directive Compliance: | EU CE Mark |
| UK Regulation Compliance: | UKCA Mark |
History
| Update and Revision: | Revision Number: 0.211 Revision Date: 12-22-2023 |
Part Numbers
Variants
| Item # | Color | Putup Type | Length | EAN |
|---|---|---|---|---|
| PRG11A2.00500 | White | Reel | 500 m | 8719605105813 |