Description
Product Overview
| Suitable Applications: | For outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and /or horizontal cabling. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches and /or tubes. Suitable for Direct Burial. |
Fiber Specifications
| Fiber Type: | OS2, G.652.D |
| Fiber Core Diameter: | 9 µm |
| Fiber Diameter: | 125 µm |
| Buffer Material: | PBT Polybutylene Terephthalate |
| Fiber Count: | 4 |
| Fiber Color Coding: | TIA-598-D |
Cable Construction
| Number of Active Subunits: | 1 |
| Number of Fillers: | 5 |
| Fibers Per Subunit: | 4 |
| Subunit Waterblocking: | Gel Filled |
| Subunit Color: | Blue |
| Central Strength Member: | Steel Rod |
Inner Jacket Specifications
| Material: | LSZH – Low Smoke Zero Halogen (Flame Retardant) |
| Color: | Black |
| Number of Ripcords: | 1 |
Armor Specifications
| Armor Type and Material: | CST – Corrugated Steel Tape |
Outer Jacket Specifications
| Jacket Material: | LSZH – Low Smoke Zero Halogen (Flame Retardant) |
| Nom. Diameter: | 13.2 mm (0.520 in) |
| Color: | Black |
| Number of Ripcords: | 1 |
Optical Characteristics
| Wavelength | 1310 nm | 1550 nm |
|---|---|---|
| Max. Attenuation | 0.36 dB/km | 0.22 dB/km |
| Mode Field Diameter | 9.2 µm | 10.4 µm |
Mechanical Characteristics
| Min. Bend Radius During Installation: | 330 mm |
| Min. Bend Radius During Operation: | 165 mm |
| Max. Tensile Strength During Installation: | 3000 N (670 lbf) |
| Max. Tensile Strength During Operation: | 1000 N (220 lbf) |
| Crush Resistance: | 3000N/100mm |
| Bulk Cable Weight: | 246 kg/km (165 lbs/1000ft) |
Temperature Range
| Operating Temperature Range: | – 40°C to +70°C |
| Storage Temperature Range: | – 40°C to +70°C |
Standards and Compliance
| Environmental Suitability: | Indoor, Outdoor, Sunlight Resistance, UV Resistance, Burial |
| Flammability / Reaction to Fire: | IEC 60332-3-24 |
| ISO/IEC Compliance: | IEC 60793-1-1 |
| European Directive Compliance: | EU Directive 2011/65/EU (RoHS 2) |
History
| Update and Revision: | Revision Number: 0.24 Revision Date: 12-07-2023 |