Product Overview
Suitable Applications: |
Shipbuilding, in-cabin passenger Wi-Fi, high-bandwidth IPTV, PoE lighting, device charging stations, onboard security cameras, etc. |
Physical Characteristics (Overall)
AWG |
Stranding |
Material |
No. of Pairs |
23 |
Solid |
BC – Bare Copper |
8 |
Material |
Nominal Diameter |
PO – Polyolefin (Foam) |
1.35 mm |
Number |
Color |
Pair 1 |
White & Blue |
Pair 2 |
White & Orange |
Pair 3 |
White & Green |
Pair 4 |
White & Brown |
Type |
Material |
Tape |
Bi-Laminate (Alum+Poly) |
Drainwire Material |
Drainwire AWG |
Tinned Copper |
28 AWG |
Material |
Nominal Diameter |
Diameter +/- Tolerance |
LSZH – Low Smoke Zero Halogen (SHF1) |
7.5 mm |
0.3 mm |
Construction and Dimensions
Min Elongation at Breakof Jacket: |
125 % |
Min Tensile Strength of Jacket: |
9 MPa |
Min Tensile Strength of Jacket Aged: |
30 % |
Min Elongation at Break of Jacket Aged: |
30 % |
Electrical Characteristics
Max. Conductor DCR |
Max DCR Unbalanced Between Pairs [%] |
Max. DCR Unbalanced Within Pair [%] |
95 Ohm/km |
4 % |
2 % |
Max. Capacitance Unbalance |
Max. Mutual Capacitance |
160 pF/100m |
56 pF/m |
Insulation Resistance: |
5000 MOhm.m |
Nominal Characteristic Impedance |
100 Ohm |
Max. Delay Skew |
Nominal Velocity of Propagation (VP) [%] |
45 ns/100m |
77% |
Frequency [MHz] |
Max. Insertion Loss (Attenuation) |
Min. NEXT [dB] |
Min. PSNEXT [dB] |
Min. ACR [dB] |
Min. PSACR [dB] |
Min. ACRF (ELFEXT) [dB] |
Min. PSACRF (PSELFEXT) [dB] |
Min. RL (Return Loss) [dB] |
Min. PSANEXT |
Min. PSAACRF |
Min. TCL [dB] |
Min. ELTCTL [dB] |
1 MHz |
2.1 dB/100m |
75.3 dB |
72.3 dB |
73.2 dB |
70.2 dB |
68 dB |
65 dB |
20 dB |
67 dB |
67 dB |
40 dB |
35 dB |
4 MHz |
3.8 dB/100m |
66.3 dB |
63.3 dB |
62.5 dB |
59.5 dB |
56 dB |
53 dB |
23 dB |
67 dB |
66.2 dB |
34 dB |
23 dB |
10 MHz |
5.9 dB/100m |
60.3 dB |
57.3 dB |
54.4 dB |
51.4 dB |
48 dB |
45 dB |
25 dB |
67 dB |
58.2 dB |
30 dB |
15 dB |
16 MHz |
7.5 dB/100m |
57.2 dB |
54.2 dB |
49.7 dB |
46.7 dB |
43.9 dB |
40.9 dB |
25 dB |
67 dB |
54.1 dB |
28 dB |
10.9 dB |
31.3 MHz |
10.5 dB/100m |
52.9 dB |
49.9 dB |
42.4 dB |
39.4 dB |
38.1 dB |
35.1 dB |
23.6 dB |
67 dB |
48.3 dB |
25.1 dB |
5.1 dB |
62.5 MHz |
15.0 dB/100m |
48.4 dB |
45.4 dB |
33.4 dB |
30.4 dB |
32.1 dB |
29.1 dB |
21.5 dB |
65.6 dB |
42.3 dB |
22 dB |
|
100 MHz |
19.1 dB/100m |
45.3 dB |
42.3 dB |
26.2 dB |
23.2 dB |
28 dB |
25 dB |
20.1 dB |
62.5 dB |
38.2 dB |
20 dB |
|
125 MHz |
21.5 dB/100m |
43.8 dB |
40.8 dB |
22.3 dB |
19.3 dB |
26.1 dB |
23.1 dB |
19.4 dB |
61 dB |
36.3 dB |
19 dB |
|
200 MHz |
27.6 dB/100m |
40.8 dB |
37.8 dB |
13.2 dB |
10.2 dB |
22 dB |
19 dB |
18 dB |
58 dB |
32.2 dB |
17 dB |
|
250 MHz |
31.1 dB/100m |
39.3 dB |
36.3 dB |
8.2 dB |
5.2 dB |
20 dB |
17 dB |
17.3 dB |
56.5 dB |
30.2 dB |
16 dB |
|
350 MHz |
34.3 dB/100m |
37.1 dB |
34.1 dB |
|
|
17.1 dB |
14.1 dB |
17.3 dB |
54.3 dB |
27.3 dB |
|
|
500 MHz |
45.3 dB/100m |
34.8 dB |
31.8 dB |
|
|
14 dB |
11 dB |
17.3 dB |
52 dB |
24.2 dB |
|
|
Table Notes: |
Limits below 4 MHz are for information only. Reference standard: ISO/IEC 61156-5 ed. 2.0 (2009) |
Coupling Attenuation Class: |
Type Ib |
Transfer Impedance Class: |
Grade 2 |
Voltage Rating [V] |
72 V DC |
Temperature Range
Installation Temperature Range: |
-5°C To +80°C |
Operating Temperature Range: |
-40°C To +80°C |
Mechanical Characteristics
Bending Test: |
Low temperature bending test -40 °C : No cracks |
Pressure Test for Jacket: |
Test at high temperature IEC 60811-508 80±2 °C 4h : ? 50 % |
Heat Stroke Test: |
Heat Shock test at (150±3°C ,1h) : No cracks |
Bulk Cable Weight: |
115 kg/km |
Min. Bend Radius During Installation: |
10*D |
Standards
ISO/IEC Compliance: |
ISO/IEC 11801-2, IEC 60092-360 |
CENELEC Compliance: |
EN 50173-1 |
Data Category: |
Category 6A |
ANSI Compliance: |
ANSI/TIA 568.2-D (2018) |
IEEE Compliance: |
IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
Applicable Environmental and Other Programs
Environmental Space: |
Indoor |
Suitability
Suitability – Indoor: |
Yes |
Flammability, LS0H, Toxicity Testing
IEC Flammability: |
IEC 60332-1-2, IEC 60332-3-22 |
Fluorine Content Test IEC60684-2: |
HF ? 0.1% |
IEC 60754-1 – Halogen Amount: |
HCL+HBr ? 0.5% |
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: |
10 µS/mm |
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: |
4.3 |
IEC 61034-2 – Smoke Density Min. Transmittance: |
60% |
Related Part Numbers
Footnote: |
*Ordering stock code will be created at the time of placing the order and the stock code will include cable part code, outer jacket color & putup length. |
Product Notes
Notes: |
LR (Lloyds Register) certification |
History
Update and Revision: |
Revision Number: 0.50 Revision Date: 12-12-2023 |