H126T01 – H126T01 – Broadband Coax, H126T, 18 AWG Solid BC, Tri-shield, LSZH Jkt

Call for Price

Compare
SKU: H126T01 Categories: , ,

Description

Product Overview

Suitable Applications: Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas

Construction Details

RG Type: 6
Conductor
No. of Elements Size Stranding Nom. Diameter Material
1 18 AWG Solid 1 mm BC – Bare Copper
Insulation
Material Nom. Insulation Diameter
PE – Polyethylene (Foam) 4.57 mm (0.180 in)
Table Notes: Gas Injected
Outer Shield
Layer Outer Shield Type Material Coverage
1 Tape Tri-Laminate (Alum+Poly+Alum) 100%
2 Braid Tinned Copper (TC) 65%
3 Tape Tri-Laminate (Alum+Poly+Alum) 100%
Outer Jacket
Material Nom. Diameter
LSZH – Low Smoke Zero Halogen (Flame Retardant) 6.9 mm
Table Notes: According to European Standard EN 50290-2-20

Electrical Characteristics

Regularity of Impedance: 40 dB
Return Loss (RL)
Frequency Min. Return Loss Min. Structural Return Loss
5-470 MHz 20 dB 20 dB
470-1000 MHz 18 dB 18 dB
1000-2000 MHz 16 dB 16 dB
2000-3000 MHz 15 dB 15 dB
Table Notes: Max. 3 peak values 4 dB lower than specified
Attenuation
Frequency Nom. Attenuation
5 MHz 1.8 dB/100m
50 MHz 4.7 dB/100m
100 MHz 6.5 dB/100m
230 MHz 9.8 dB/100m
400 MHz 13 dB/100m
800 MHz 18.7 dB/100m
862 MHz 19.5 dB/100m
1000 MHz 21.1 dB/100m
1350 MHz 24.9 dB/100m
1750 MHz 28.8 dB/100m
2150 MHz 32.3 dB/100m
2400 MHz 34.4 dB/100m
3000 MHz 39.2 dB/100m
Table Notes: Maximum attenuation is 10% higher
Electricals
Max. Conductor DCR Nom. Outer Shield DCR Nom. Capacitance
Cond-to-Shield
Nom. Characteristic Impedance Nom. Velocity of Prop.
23 Ohm/km (7.0 Ohm/1000ft) 12 Ohm/km (3.7 Ohm/1000ft) 54 pF/m (16 pF/ft) 75 Ohm 82%
Transfer Impedance
Max. Transfer Impedance
2.5 mOhm/m
Screening
Frequency Min. Screening Attenuation
30-1000 MHz 95
1000-2000 MHz 85
2000-3000 MHz 75
Screening Class: A+

Mechanical Characteristics

Temperature
Operating Storage
-30°C To +70°C -30°C To +70°C
Bend Radius
Stationary Min.
65 mm (2.6 in)
Bulk Cable Weight: 48 kg/km

Standards and Compliance

Environmental Suitability: Indoor – Euroclass Dca
Flammability / Reaction to Fire: IEC 60332-1-2
CPR Compliance: CPR Euroclass: Dca-s2,d1,a1
CENELEC Compliance: EN 50117-1
European Halogen Free Standards: IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 – Halogen Amount = Zero, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 2.5 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3
UK Regulation Compliance: UKCA Mark

History

Update and Revision: Revision Number: 0.178 Revision Date: 02-05-2024

Part Numbers

Variants
Item # Color Putup Type Length EAN
H126T01.01500 White Reel 500 m 8719605087690