H1000LW – H1000LW – 50 Ohm Wireless Transmission Coax, H1000, RG8, 10 AWG Solid BC, CU-Foil + 50% BC Braid, LSZH Jkt, CPR: Cca

Call for Price

Compare

Description

Product Overview

Suitable Applications: Point-to-point and point-to-multipoint wireless antenna communication; Wireless microphones, Two-Way Radios, Amateur (Ham) Radio, Low Power FM, GPS, RFID (Radio Frequency Identification)

Construction Details

RG Type: 8
Conductor
No. of Elements Size Stranding Nom. Diameter Material
1 10 AWG Solid 2.62 mm BC – Bare Copper
Insulation
Element Material Nom. Insulation Diameter
Insulated Conductor PE – Polyethylene (Foam) 7.15 mm (0.281 in)
Table Notes: Centricity min. 85%
Outer Shield
Layer Outer Shield Type Material Coverage
1 Tape Bi-Laminate (Bare Copper+Poly) 100%
2 Braid Bare Copper (BC) 50%
Outer Jacket
Material Nom. Diameter
LSZH – Low Smoke Zero Halogen (Flame Retardant) 10.3 mm
Table Notes: According to European Standard EN 50290-2-20

Electrical Characteristics

Regularity of Impedance: Min. 46 dB
Attenuation
Frequency Nom. Attenuation
5 MHz 0.8 dB/100m
50 MHz 2.8 dB/100m
100 MHz 4 dB/100m
200 MHz 5.7 dB/100m
400 MHz 8.4 dB/100m
600 MHz 10.5 dB/100m
800 MHz 12.3 dB/100m
1000 MHz 14 dB/100m
1350 MHz 16.7 dB/100m
1750 MHz 19.5 dB/100m
2150 MHz 22.1 dB/100m
2400 MHz 23.6 dB/100m
5000 MHz 37.4 dB/100m
10000 MHz 59.3 dB/100m
Table Notes: Max. attenuation 10% higher
Electricals
Max. Conductor DCR Nom. Outer Shield DCR Nom. Capacitance
Cond-to-Shield
Nom. Characteristic Impedance Nom. Velocity of Prop.
3.5 Ohm/km (1.1 Ohm/1000ft) 12 Ohm/km (3.7 Ohm/1000ft) 80 pF/m (24 pF/ft) 50 Ohm 83%
Screening
Frequency Min. Screening Attenuation
30 – 1000 MHz 90 dB

Mechanical Characteristics

Temperature
Operating Installation Storage
-30°C To +70°C -5°C To +50°C -30°C To +70°C
Bend Radius
Stationary Min.
100 mm (3.9 in)

Standards and Compliance

Environmental Suitability: Indoor – Euroclass Cca
Flammability / Reaction to Fire: IEC 60332-1-2, IEC 60332-3-24, CEI 20-22-3
CPR Compliance: CPR Euroclass: Cca-s1,d2,a1
ISO/IEC Compliance: IEC 61196, IEC 61034-2 – Smoke Density Min Transmittance = 60%
European Halogen Free Standards: IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 – Halogen Amount = Zero, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 2.5 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3
European Directive Compliance: EU CE Mark

History

Update and Revision: Revision Number: 0.30 Revision Date: 11-09-2022