DA1695A – Distributed Antenna System RG6 Type BC Coax, CMP

Call for Price

Compare

Description

Product Overview

Suitable Applications: Distributed Antenna System

Physical Characteristics (Overall)

Conductor
AWG Stranding Material Nominal Diameter No. of Coax
18 Solid BC – Bare Copper 0.040 in 1
Insulation
Material Nominal Diameter
FEP – Fluorinated Ethylene Propylene (Foam) 0.17 in
Outer Shield
Type Layer Material Material Trade Name Coverage [%]
Tape 1 Tri-Laminate (Alum+Poly+Alum) Duofoil® 100%
Braid 2 Tinned Copper (TC) 95%
Outer Jacket
Material Nominal Diameter
PVC – Polyvinyl Chloride 0.229 in

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR
6.4 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to Shield
16.2 pF/ft
Inductance
Nominal Inductance
0.103 µH/ft
Impedance
Nominal Characteristic Impedance
75 Ohm
Return Loss (RL)
Frequency [MHz] Minimum Return (RL)
5 – 1000 MHz 20 dB
1000 – 3000 MHz 15 dB
High Frequency (Nominal/Typical)
Frequency [MHz] Nom. Insertion Loss
1 MHz 0.24 dB/100ft
3.58 MHz 0.45 dB/100ft
5 MHz 0.55 dB/100ft
7 MHz 0.65 dB/100ft
10 MHz 0.75 dB/100ft
67.5 MHz 1.74 dB/100ft
71.5 MHz 1.78 dB/100ft
88.5 MHz 1.94 dB/100ft
100 MHz 2.1 dB/100ft
135 MHz 2.4 dB/100ft
143 MHz 2.5 dB/100ft
180 MHz 2.8 dB/100ft
270 MHz 3.4 dB/100ft
360 MHz 4.0 dB/100ft
540 MHz 5.2 dB/100ft
720 MHz 6.1 dB/100ft
750 MHz 6.2 dB/100ft
1000 MHz 7.4 dB/100ft
1500 MHz 9.5 dB/100ft
2000 MHz 11.3 dB/100ft
2250 MHz 12.2 dB/100ft
3000 MHz 14.6 dB/100ft
Delay
Nominal Delay Nominal Velocity of Propagation (VP) [%]
1.22 ns/ft 83%
Voltage
UL Voltage Rating
300 V RMS
Electrical Characteristics Notes: Return Loss: Fixed bridge and termination

Temperature Range

UL Temp Rating: 75°C
Operating Temperature Range: -20°C To +75°C

Mechanical Characteristics

UV Resistance: No
Bulk Cable Weight: 37 lbs/1000ft
Max. Pull Tension: 69 lbs
Min. Bend Radius/Minor Axis: 2.5 in

Standards

NEC/(UL) Compliance: CMP
CEC/C(UL) Compliance: CMP
RG Type: 6

Applicable Environmental and Other Programs

Environmental Space: Indoor – Plenum
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/11/EC (BFR): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: Yes

Suitability

Suitability – Aerial: No
Suitability – Burial: No
Suitability – Hazardous Locations: No
Suitability – Indoor: Yes
Suitability – Outdoor: No
Suitability – Sunlight Resistance: No

Flammability, LS0H, Toxicity Testing

UL Flammability: NFPA 262
CSA Flammability: FT6
UL voltage rating: 300 V RMS

Plenum/Non-Plenum

Plenum (Y/N): Yes

Related Part Numbers

Non-Plenum Number: DA1694A
Variants
Item # Color Put-Up Type Length UPC
DA1695A 0101000 Black Reel 1,000 ft 612825285229
DA1695A 0103000 Black Reel 3,000 ft 612825285236
DA1695A 0105000 Black Reel 5,000 ft 612825285243
DA1695A 8771000 Natural Reel 1,000 ft 612825285250
DA1695A 8773000 Natural Reel 3,000 ft 612825285267
DA1695A 8775000 Natural Reel 5,000 ft 612825285274
Footnote: C – CRATE REEL PUT-UP.

History