Product Overview

Suitable Applications: Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas

Construction Details

Conductor
No. of Elements Size Stranding Nom. Diameter Material
1 18 AWG Solid 1.1 mm BC – Bare Copper
Insulation
Material Nom. Insulation Diameter
PE – Polyethylene (Foam) 4.8 mm (0.19 in)
Table Notes: Gas Injected
Outer Shield
Layer Outer Shield Type Material Coverage
1 Tape Tri-Laminate (Alum+Poly+Alum) 100%
2 Braid Tinned Copper (TC) 70%
3 Tape Bi-Laminate (Alum+Poly) 100%
Table Notes: Foil Tape has L-Fold and is bonded to the sheath
Outer Jacket
Material Nom. Diameter
PVC – Polyvinyl Chloride 7.1 mm
Table Notes: According to European Standard EN 50290-2-20

Electrical Characteristics

Regularity of Impedance: 40 dB
Return Loss (RL)
Frequency Min. Return Loss
30-470 MHz 27 dB
470-1000 MHz 24 dB
1000-2000 MHz 18 dB
2000-3000 MHz 16 dB
Attenuation
Frequency Nom. Attenuation
5 MHz 1.5 dB/100m
50 MHz 4.0 dB/100m
100 MHz 5.7 dB/100m
200 MHz 8.2 dB/100m
400 MHz 11.8 dB/100m
600 MHz 14.7 dB/100m
800 MHz 17.2 dB/100m
1000 MHz 19.4 dB/100m
1350 MHz 23.0 dB/100m
1750 MHz 27.0 dB/100m
2000 MHz 28.7 dB/100m
2150 MHz 30.0 dB/100m
2400 MHz 32.0 dB/100m
3000 MHz 36.0 dB/100m
Table Notes: Maximum attenuation is 10% higher
Electricals
Max. Conductor DCR Nom. Outer Shield DCR Nom. Capacitance
Cond-to-Shield
Nom. Characteristic Impedance Nom. Velocity of Prop.
19 Ohm/km (5.8 Ohm/1000ft) 14 Ohm/km (4.3 Ohm/1000ft) 51 pF/m (16 pF/ft) 75 Ohm 86%
Transfer Impedance
Frequency Max. Transfer Impedance
5-30 MHz max. 2.5 mOhm/m
Screening
Frequency Min. Screening Attenuation
30-1000 MHz 95 dB
1000-2000 MHz 85 dB
2000-3000 MHz 75 dB
Screening Class: A+

Mechanical Characteristics

Temperature
Operating Storage
-40°C To +70°C -40°C To +70°C
Bend Radius
Stationary Min.
35 mm (1.4 in)
Max. Pull Tension: 60 N (13 lbf)
Bulk Cable Weight: 51 kg/km

Standards and Compliance

Environmental Suitability: Indoor – Euroclass Eca
Flammability / Reaction to Fire: IEC 60332-1-2
CPR Compliance: CPR Euroclass: Eca
CENELEC Compliance: EN 50117-1
UK Regulation Compliance: UKCA Mark

History

Update and Revision: Revision Number: 0.110 Revision Date: 12-19-2022