CTF125 – CTF125 – Broadband Coax, 16 AWG Solid BC, Foil + 50% BC Braid, PVC Jkt

Call for Price

Compare
SKU: CTF125 Categories: , , ,

Description

Product Overview

Suitable Applications: Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas

Construction Details

RG Type: 7/U Type
Conductor
No. of Elements Size Stranding Nom. Diameter Material
1 16 AWG Solid 1.25 mm BC – Bare Copper
Insulation
Element Material Nom. Insulation Diameter
Insulated Conductor PE – Polyethylene (Foam) 5.4 mm (0.21 in)
Outer Shield
Layer Outer Shield Type Material Coverage
1 Tape Bi-Laminate (Bare Copper+Poly) 100%
2 Braid Bare Copper (BC) 50%
Outer Jacket
Material Nom. Diameter
PVC – Polyvinyl Chloride 7.8 mm

Electrical Characteristics

Regularity of Impedance: Min. 40 or max. 1% dB
Return Loss (RL)
Frequency Min. Return Loss
5-470 MHz 23 dB
470 – 1000 MHz 20 dB
1000 – 2000 MHz 18 dB
2000 – 3000 MHz 16 dB
Table Notes: In each frequency band, 3 peak values up to 4 dB lower are allowed
Attenuation
Frequency Nom. Attenuation
5 MHz 1.5 dB/100m
50 MHz 3.5 dB/100m
100 MHz 5 dB/100m
200 MHz 7.5 dB/100m
460 MHz 11.5 dB/100m
800 MHz 14.9 dB/100m
860 MHz 15.5 dB/100m
1000 MHz 17 dB/100m
1750 MHz 22.8 dB/100m
2150 MHz 26 dB/100m
2400 MHz 28 dB/100m
3000 MHz 32 dB/100m
Electricals
Max. Conductor DCR Nom. Outer Shield DCR Nom. Capacitance
Cond-to-Shield
Nom. Characteristic Impedance Nom. Velocity of Prop.
16 Ohm/km (4.9 Ohm/1000ft) 13.5 Ohm/km (4.11 Ohm/1000ft) 54 pF/m (16 pF/ft) 75 Ohm 81%
Screening
Frequency Min. Screening Attenuation
30 – 1000 MHz 75 dB
1000 – 2000 MHz
2000 – 3000 MHz

Mechanical Characteristics

Temperature
Operating Installation Storage
-40°C To +70°C -5°C To +50°C -40°C To +70°C
Bend Radius
Stationary Min.
40 mm (1.6 in)

Standards and Compliance

Environmental Suitability: Indoor – Euroclass Eca
Flammability / Reaction to Fire: IEC 60332-1-2
CPR Compliance: CPR Euroclass: Eca
CENELEC Compliance: EN 50117-1EN 50117-9-2EN 50290-2-20
European Directive Compliance: EU CE Mark
UK Regulation Compliance: UKCA Mark

History

Update and Revision: Revision Number: 0.209 Revision Date: 03-30-2023