Category 3 Backbone Cable, 100 Pair, U/UTP, CMP (Category 3 Cable) – Belden (DPLN100)

Call for Price

Category 3 Premise Backbone Cable (16MHz), DIW 100 Pair, 24 AWG Solid Bare Copper Conductors, U/UTP, Plenum-CMP, PVC-LS Jacket
Belden’s DataTwist 3 products come in a variety of pair counts ranging from 2 to 400 in riser and plenum. ATMM (corrugated aluminum tape) versions are also available for added crush resistance.

Compare
SKU: BELDEN-DPLN100 Categories: , , ,

Description

Features & Benefits

  • Rugged Design: Cables meet and exceed ANSI/TIA-568-C.2 and CSA T529-95 specifications
  • Engineered to Perform: High-value UTP cable engineered to perform to Category 3 requirements per ANSI/TIA-568-C.2

Specifications

Product Overview

Suitable Applications

Premise Backbone Cable, Ethernet 10BASE-T, Analog Phone, FAX

Construction Details

Conductor

Size Stranding Material No. of Pairs
24 AWG Solid BC – Bare Copper 100

Insulation

Material Color Code
PVC – Polyvinyl Chloride Western Electric (Non-Striped) Bound in 25 Pair Sub-Units, Binder 1: Blue/White, Binder 2: Orange/White, Binder 3: Green/White, Binder 4: Brown/White

Outer Jacket

Material Material Trade Name Nom. Diameter Ripcord
PVC – Polyvinyl Chloride Flamarrest® 0.775 in (19.7 mm) Yes

Electrical Characteristics

Electricals

Max. Conductor DCR Max. Capacitance Unbalance
93.8 Ohm/km (28.6 Ohm/1000ft) 330 pF/100m

Delay

Frequency Max. Delay Max. Delay Skew Nom. Velocity of Prop.
16 MHz 543 ns/100m 45 ns/100m 61%

High Frequency

Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. RL (Return Loss) [dB] Max./Min. Fitted Impedance [Ohm]
0.772 2.2 dB/100m 47.0 43.0 50.1 46.1
1 2.6 dB/100m 45.0 41.0 47.8 43.8 12.0 100 ± 15
4 5.6 dB/100m 36.0 32.0 36.0 32.0 12.0 100 ± 15
8 8.5 dB/100m 31.0 28.0 28.3 24.3 12.0 100 ± 15
10 9.7 dB/100m 30.0 26.0 26.2 22.3 12.0 100 ± 15
16 13.1 dB/100m 27.0 23.0 20.1 16.1 10.0 100 ± 15

Voltage

UL Voltage Rating
300 V (CMP)

Mechanical Characteristics

Temperature

UL Temperature Operating Installation Storage
60°C -30°C To +60°C 0°C To +50°C -30°C To +60°C

Bend Radius

Stationary Min. Installation Min.
7.75 in (197 mm) 15.5 in (394 mm)

Max. Pull Tension

Part Numbers

Item # Color Putup Type Length UPC
DPLN100 732CUT Olive Cut to Length 612825061014
DPLN100 732CUT Olive Cut to Length 1 ft 612825061014

Systems to Support Key Applications
Blade Slot Selection Table

Brand

Belden