Description
Features & Benefits
- Built to Last: Enjoy peace of mind in the field with a reliable, ruggedized solution that lasts over time
- Consistent Performance: Designed for high-volume data transfer after installation to maintain maximum uptime
- Extensive Product Portfolio: Choose the best cable for your application with a wide variety of options to meet your needs
Specifications
Product Overview
Suitable Applications |
RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, …); Low Voltage Digital Control (24v, …); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc. |
---|
Construction Details
Conductor
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Pair(s) | 2 | 24 AWG | 7×32 | TC – Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Pair(s) | FEP – Fluorinated Ethylene Propylene (Foam) | 0.019 in (0.48 mm) | 0.062 in (1.6 mm) | White/Blue Stripe & Blue/White Stripe, White/Orange Stripe & Orange/White Stripe |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7×32) TC |
Braid | Tinned Copper (TC) | 90% |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC – Polyvinyl Chloride | 0.015 in (0.38 mm) | 0.273 in (6.93 mm) |
Overall Cable Diameter (Nominal) |
0.273 in (6.93 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|---|---|---|---|---|---|
Pair(s) | 24 Ohm/1000ft | 12 pF/ft (39 pF/m) | 22 pF/ft | 120 Ohm | 76% | 3.2 Amps per Conductor at 25ºC |
Nom. Outer Shield DCR |
2.4 Ohm/1000ft (7.9 Ohm/km) |
---|
High Frequency (Nominal/Typical)
Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
---|---|---|
Pair(s) | 1 | 0.6 dB/100ft |
Voltage
UL Voltage Rating |
---|
300 V (CMP) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|---|
75°C | 0°C to +75°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
2.75 in (69.9 mm) | 2.75 in (69.9 mm) |
Max. Pull Tension |
56.7 lbs (25.7 kg) |
---|---|
Bulk Cable Weight |
38 lbs/1000ft |
Standards and Compliance
Environmental Suitability |
Indoor |
||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flammability / Reaction to Fire |
NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
||||||||||||||||
CPR Compliance |
CPR Euroclass: Eca |
||||||||||||||||
NEC / UL Compliance |
Article 800, CMP |
Item # | Color | UPC | Footnote |
---|---|---|---|
82842 8771000 | Natural | 612825198192 | C |
82842 877500 | Natural | 612825198208 | C |
82842 8775000 | Natural | 612825198215 |
Belden Industrial Ethernet Cable Brochure
Belden Industrial Ethernet Cable Selector