Fieldbus, 1 Pr #18 Str TC, PP ins, OS, PVC Jkt, AIA Armor, PVC Jkt, ISA/SP-50 Type A, PLTC, CM (Category 6A Cable) – Belden (123076F)
Fieldbus, 1 Pair 18AWG (7×26) Tinned Copper, PP insulation, Overall Beldfoil® Shield, PVC Inner Jacket, Aluminum Interlock Armor, PVC Outer Jacket, ISA/SP-50 Type A, , PLTC, CM
Our Category 6A Copper Cable offers a wide range of options for your CAT 6A network. Some options that are available include small diameter, snake, industrial, non-bonded, and patented Bonded-Pair. The 10GXS Cable is the industry’s gold standard for performance, while, Belden’s newest cable, 10GXW, is the industry’s smallest-diameter Category 6A cable designed for smart building and multi-gigabit applications with performance optimized for in-building wireless networks.
Call for Price
Features & Benefits
- Reliable network performance: Designed for mission-critical situations that require constant uptime, whether indoor or outside
- Best-in-class system noise immunity: Achieved through outstanding cable balance, is less susceptible to RFI/EMI in noisy environments
- Reduce installation time and costs: 10GXW is the smallest and lightest horizontal Category 6A cable available
- Unparalleled performance: Full 100m channel length under 100W PoE load without derating up to 60°C using 10GXS cables
- Designed to Last: Higher pulling tensions and tighter bend radii offered by Bonded-Pair Cables
Specifications
Product Overview
|
Suitable Applications |
exposure to rodent, crush, or cut through force, harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc. |
|---|
Construction Details
Conductor
| Element | No. of Elements | Size | Stranding | Material |
|---|---|---|---|---|
| Pair(s) | 1 | 18 AWG | 7×26 | TC – Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Color Code |
|---|---|---|---|
| Pair(s) | PP – Polypropylene | 0.022 in (0.56 mm) | Blue & Orange |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 20 AWG (7×28) TC |
Inner Jacket
| Material | Nom. Diameter |
|---|---|
| PVC – Polyvinyl Chloride | 0.280 in (7.11 mm) |
Armor
| Armor Type & Material |
|---|
| AIA – Aluminum Interlock Armor |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter |
|---|---|---|
| PVC – Polyvinyl Chloride | 0.045 in (1.1 mm) | 0.585 in (14.9 mm) |
|
Overall Cable Diameter (Nominal) |
0.585 in (14.9 mm) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Shield | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|---|---|---|---|---|
| Pair(s) | 5.86 Ohm/1000ft (19.2 Ohm/km) | 45 pF/ft | 100 Ohm | 66% | 5.2 Amps per Conductor |
|
Nom. Outer Shield DCR |
7.5 Ohm/1000ft (25 Ohm/km) |
|---|
High Frequency (Nominal/Typical)
| Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
|---|---|---|
| Pair(s) | 0.039 | 0.08 dB/100ft |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) |
|---|---|
| 0.031 | 0.091 dB/100ft |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CM, PLTC) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|---|
| 105°C | -40°C to +105°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 6 in (150 mm) | 6 in |
|
Max. Pull Tension |
60 lbs (27 kg) |
|---|---|
|
Bulk Cable Weight |
38 lbs/1000ft (57 kg/km) |
DataTuff Fiber Optic Renewable Grade Cable
Copper Catalog