Product Overview
Suitable Applications: |
harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc. |
Physical Characteristics (Overall)
Element |
AWG |
Stranding |
Material |
No. of Conductors |
Conductor(s) |
10 |
7×18 |
BC – Bare Copper |
15 |
Material |
Nominal Diameter |
Nominal Wall Thickness |
PVC/Nylon – Polyvinyl Chloride + Nylon |
0.164 in |
0.026 in |
Number |
Color |
1 |
Black and Numbered 1 |
2 |
Red and Numbered 2 |
3 |
Blue and Numbered 3 |
4 |
Orange and Numbered 4 |
5 |
Yellow and Numbered 5 |
6 |
Brown and Numbered 6 |
7 |
Red/Black and Numbered 7 |
8 |
Blue/Black and Numbered 8 |
9 |
Orange/Black and Numbered 9 |
10 |
Yellow/Black and Numbered 10 |
11 |
Brown/Black and Numbered 11 |
12 |
Black/Red and Numbered 12 |
13 |
Blue/Red and Numbered 13 |
14 |
Orange/Yellow and Numbered 14 |
15 |
Yellow/Red and Numbered 15 |
Type |
Material |
Material Trade Name |
Coverage [%] |
Drainwire Material |
Drainwire AWG |
Tape |
Bi-Laminate (Alum+Poly) |
Beldfoil® |
100% |
TC – Tinned Copper |
10 |
Material |
Nominal Diameter |
Nominal Wall Thickness |
PVC – Polyvinyl Chloride |
0.941 in |
0.083 in |
Electrical Characteristics
Nominal Conductor DCR |
1.04 Ohm/1000ft |
Max. Recommended Current [A] |
20 Amps per Conductor at 30ºC |
Description |
UL Description |
UL Voltage Rating |
Voltage Rating [V] |
Type TC |
TC |
600 V RMS (Type TC) |
600 V RMS (Type TC) |
Temperature Range
UL Temp Rating: |
90°C Dry, 90°C Wet |
Operating Temperature Range: |
-30°C To +90°C |
Wet Temp Range: |
-30°C To +90 °C |
Dry Temp Range: |
-30°C To +90 °C |
Mechanical Characteristics
Bulk Cable Weight: |
768 lbs/1000ft |
Max. Pull Tension: |
1245 lbs |
Min Bend Radius (Overall): |
9.4 in |
Min. Bend Radius/Minor Axis: |
9.41 in |
Standards
NEC/(UL) Compliance: |
TC-ER, THWN-2 |
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2011/65/EU (RoHS 2): |
Yes |
EU Directive 2012/19/EU (WEEE): |
Yes |
EU Directive 2015/863/EU (RoHS 2 amendment): |
Yes |
EU Directive Compliance: |
Yes |
Suitability
Suitability – Burial: |
Yes |
Suitability – Indoor: |
Yes |
Suitability – Outdoor: |
Yes |
Suitability – Sunlight Resistance: |
Yes |
Flammability, LS0H, Toxicity Testing
UL Flammability: |
UL 1685 UL Loading |
UL voltage rating: |
600 V RMS (Type TC) |
Plenum/Non-Plenum
Related Part Numbers
Item # |
Put-Up Type |
A1510K 0102500 |
Reel |
History
Update and Revision: |
Revision Number: 0.51 Revision Date: 01-10-2024 |