Product Overview
Suitable Applications: |
Internal interconnection, internal wiring of electronic equipment, color-coded for quick identification & circuit tracing, easy breakouts for circuit routing, designed for mass-termination with standard IDC connectors |
Physical Characteristics (Overall)
AWG |
Stranding |
Material |
28 |
7×36 |
TC – Tinned Copper |
Material |
Nominal Wall Thickness |
PVC – Polyvinyl Chloride |
0.010 in |
Number |
Color |
1 |
Brown |
2 |
Red |
3 |
Orange |
4 |
Yellow |
5 |
Green |
6 |
Blue |
7 |
Purple |
8 |
Gray |
9 |
White |
10 |
Black |
Over 10 conductors |
Repeat as required |
Construction and Dimensions
Conductor Spacing Center-Center: |
.050 +/- .003 in |
Conductor Spacing Center-Center Outside: |
1.650 +/- .008 in |
Substrate Thickness and Material: |
.010 in, Clear PVC |
OuterJacket1, Nominal Width: |
1.700 +/- .008 in |
OuterJacket1, Nom Thick Flat Section: |
0.036 in |
Electrical Characteristics
Nominal Conductor DCR |
68.2 Ohm/1000ft |
Element |
Nom. Capacitance Conductor to Conductor |
@ 1 kHz (GSG) |
18 pF/ft |
@ 1 MHz (GS) |
10 pF/ft |
@ 1 MHz (GSG) |
15 pF/ft |
Min Insulation Resistance: |
10,000 MOhm |
Element |
Nominal Inductance |
@ 1 MHz (GS) |
0.29 µH/ft |
@ 1 MHz (GSG) |
0.2 µH/ft |
Nominal Balanced Characteristic Impedance Description |
Nominal Characteristic Impedance |
Nominal Characteristic Impedance Description |
(GS) |
150 Ohm |
(GS) |
(GSG) |
105 Ohm |
(GSG) |
High Frequency (Nominal/Typical)
Frequency [MHz] |
Nom. Insertion Loss |
10 MHz |
2.8 dB/100ft |
20 MHz |
4.8 dB/100ft |
30 MHz |
6.5 dB/100ft |
40 MHz |
8.3 dB/100ft |
50 MHz |
9.8 dB/100ft |
60 MHz |
12 dB/100ft |
70 MHz |
13 dB/100ft |
80 MHz |
14 dB/100ft |
90 MHz |
15.8 dB/100ft |
100 MHz |
17 dB/100ft |
Table Notes: |
GS=Ground-Signal Mode; GSG=Ground-Signal-Ground Mode |
Nominal Delay |
Nominal Velocity of Propagation (VP) [%] |
1.40 ns/ft |
72% |
Element |
Typical Unbalanced NEXT % |
Typical Unbalanced FEXT % |
Typical Cross Talk Pulse Rise Time (ns) |
10 ft. sample length |
4.8 |
7 |
3 ns |
10 ft. sample length |
3.5 |
4.7 |
5 ns |
10 ft. sample length |
3 |
3 |
7 ns |
Max. Recommended Current [A] |
1 Amp per Conductor at 20ºC |
Dielectric Withstand Voltage |
UL Voltage Rating |
2000 V |
300 V |
Temperature Range
Operating Temperature Range: |
-20°C to +105°C |
Mechanical Characteristics
Bulk Cable Weight: |
39 lbs/1000ft |
Min. Bend Radius/Minor Axis: |
0.5 in |
Standards
UL AWM Style Compliance: |
AWM 20932 |
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
EU Directive 2011/65/EU (RoHS 2): |
Yes |
EU Directive 2012/19/EU (WEEE): |
Yes |
EU Directive 2015/863/EU (RoHS 2 amendment): |
Yes |
EU Directive Compliance: |
Yes |
CA Prop 65 (CJ for Wire and Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Suitability
Suitability – Indoor: |
Yes |
Flammability, LS0H, Toxicity Testing
Plenum/Non-Plenum
Related Part Numbers
Item # |
Color |
Put-Up Type |
Length |
UPC |
9R28034 000100 |
None |
Reel |
100 ft |
612825221951 |
History
Update and Revision: |
Revision Number: 0.326 Revision Date: 05-05-2023 |