Product Overview
Suitable Applications: |
Internal interconnection, internal wiring of electronic equipment, reliable mass-termination to standard IDC connectors, noisy evnvironments |
Physical Characteristics (Overall)
AWG |
Stranding |
Material |
28 |
7×36 |
TC – Tinned Copper |
Material |
Nominal Wall Thickness |
PVC – Polyvinyl Chloride |
0.010 in |
Table Notes: |
First Conductor has Red Stripe |
Type |
Material |
Material Trade Name |
Coverage [%] |
Drainwire Material |
Drainwire AWG |
Drainwire Construction n x D |
Tape |
Bi-Laminate (Alum+Poly) |
Beldfoil® |
100% |
TC – Tinned Copper |
28 |
7×36 |
Material |
Nominal Wall Thickness |
PVC – Polyvinyl Chloride |
0.038 in |
Construction and Dimensions
Conductor Spacing Center-Center: |
.050 +/- .002 in |
Conductor Spacing Center-Center Outside: |
.400 +/- .008 in |
OuterJacket1, Nominal Width: |
.520 in |
OuterJacket1, Nom Thick Flat Section: |
0.115 in |
Electrical Characteristics
Nominal Conductor DCR |
68.2 Ohm/1000ft |
Element |
Nom. Capacitance Conductor to Conductor |
@ 1 kHz (GSG) with shield grounded |
70 pF/ft |
@ 1 MHz (GSG) with shield grounded |
50 pF/ft |
Min Insulation Resistance: |
10,000 MOhm |
Element |
Nominal Inductance |
@ 1 MHz (GSG) with shield grounded |
0.11 µH/ft |
Nominal Characteristic Impedance |
Nominal Characteristic Impedance Description |
45 Ohm |
(GSG) with shield grounded |
High Frequency (Nominal/Typical)
Frequency [MHz] |
Nom. Insertion Loss |
10 MHz |
6 dB/100ft |
20 MHz |
9.5 dB/100ft |
30 MHz |
12.5 dB/100ft |
40 MHz |
14.9 dB/100ft |
50 MHz |
17.2 dB/100ft |
60 MHz |
19 dB/100ft |
70 MHz |
21.5 dB/100ft |
80 MHz |
23 dB/100ft |
90 MHz |
24.5 dB/100ft |
100 MHz |
26 dB/100ft |
Table Notes: |
GSG=Ground-Signal-Ground Mode |
Nominal Delay |
Nominal Velocity of Propagation (VP) [%] |
1.7 ns/ft |
60% |
Element |
Typical Unbalanced NEXT % |
Typical Unbalanced FEXT % |
Typical Cross Talk Pulse Rise Time (ns) |
10 ft. sample length with ground connected to shield |
1.5 |
2 |
3 ns |
10 ft. sample length with ground connected to shield |
0.9 |
1.5 |
5 ns |
10 ft. sample length with ground connected to shield |
0.7 |
1.2 |
7 ns |
Max. Recommended Current [A] |
1 Amp per Conductor at 20ºC |
Dielectric Withstand Voltage |
UL Voltage Rating |
2000 V |
300 V |
Temperature Range
Operating Temperature Range: |
-20°C to +105°C |
Mechanical Characteristics
Bulk Cable Weight: |
44 lbs/1000ft |
Min. Bend Radius During Installation: |
3.0 in |
Min. Bend Radius/Minor Axis: |
1.25 in |
Standards
UL AWM Style Compliance: |
AWM 20081 |
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2003/96/EC (BFR): |
Yes |
EU Directive 2011/65/EU (RoHS 2): |
Yes |
EU Directive 2012/19/EU (WEEE): |
Yes |
EU Directive 2015/863/EU (RoHS 2 amendment): |
Yes |
EU Directive Compliance: |
EU Directive 2003/11/EC (BFR) |
CA Prop 65 (CJ for Wire and Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Suitability
Suitability – Indoor: |
Yes |
Flammability, LS0H, Toxicity Testing
Plenum/Non-Plenum
Related Part Numbers
Item # |
Color |
Put-Up Type |
Length |
UPC |
9L28309 010100 |
Black |
Reel |
100 ft |
612825221722 |
Footnote: |
E – MAY CONTAIN MORE THAN 1 PIECE. MINIMUM LENGTH OF ANY ONE PIECE IS 25′. |
History
Update and Revision: |