Description
Product Overview
| Suitable Applications: | RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, …); Low Voltage Digital Control (24v, ); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc. |
Construction Details
Conductor
| Size | Stranding | Material |
|---|---|---|
| 24 | 7×32 | TC – Tinned Copper |
Insulation
| Material | Nom. Insulation Diameter | Color Code |
|---|---|---|
| PE – Polyethylene | 1.73 mm (0.0681 in) | White/Blue & Blue/White, White/Orange & Orange/White |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7×32) TC |
| Braid | Tinned Copper (TC) | 90% |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter |
|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 0.9 mm (0.035 in) | 8.65 mm (0.341 in) |
| Table Notes: | UV Stabilised |
| Overall Cable Diameter (Nominal): | 8.65 mm (0.341 in) |
Electrical Characteristics
Electricals
| Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|---|---|---|---|---|
| 78.7 Ohm/km (24.0 Ohm/1000ft) | 42 pF/m (13 pF/ft) | 75.5 pF/m | 120 Ohm | 66% | 2.1 Amps per Conductor |
| Nom. Outer Shield DCR: | 7.2 Ohm/km (2.2 Ohm/1000ft) |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
|---|---|
| 1 | 1.97 dB/100m |
Mechanical Characteristics
Temperature
| Operating | Installation | Storage |
|---|---|---|
| -45°C To +80°C | -15°C To +80°C | -45°C To +80°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 43 mm (1.7 in) | 86 mm (3.4 in) |
| Max. Pull Tension: | 395 N (88.8 lbf) |
| Bulk Cable Weight: | 49 lbs/1000ft |
Standards and Compliance
| Environmental Suitability: | Indoor – Euroclass Dca, Indoor, Non-Halogenated, Sunlight Resistance, Oil Resistance |
| Flammability / Reaction to Fire: | IEC 60332-1-2, IEC 60332-3-24 |
| CPR Compliance: | CPR Euroclass: Dca-s2,d2,a1; CPR UKCA Class: Dca-s2,d2,a1 |
| ISO/IEC Compliance: | IEC 61034-2 – Smoke Density Min Transmittance = 60% |
| CENELEC Compliance: | EN 50290-2-20 |
| European Halogen Free Standards: | IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 – Halogen Amount = Zero, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 2.5 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3 |
| European Directive Compliance: | EU CE Mark |
| UK Regulation Compliance: | UKCA Mark |
| Other Standard Compliance(s): | DMX-512 |
History
| Update and Revision: | Revision Number: 0.471 Revision Date: 12-22-2023 |
Part Numbers
Variants
| Item # | Color | Putup Type | Length | UPC/EAN | Footnote |
|---|---|---|---|---|---|
| 9842NH.02500 | Black | Reel | 500 m | 8719605023308 | |
| 9842NH.02520 | Black | Reel | 520 m | 8719605172129 | |
| 9842NH.021000 | Black | Reel | 1,000 m | 8719605155405 | |
| 9842NH.022500 | Black | Reel | 2,500 m | 8719605023292 | |
| 9842NH.00152 | Chrome | Reel | 152 m | 8719605023230 | |
| 9842NH.00305 | Chrome | Reel | 305 m | 8719605023254 | |
| 9842NH 060500 | Chrome | Reel | 500 ft | 612825259572 | |
| 9842NH.00500 | Chrome | Reel | 500 m | 8719605023261 | |
| 9842NH 0601000 | Chrome | Reel | 1,000 ft | 612825259565 | C |
| 9842NH 0601000 | Chrome | Reel | 1,000 ft | 612825259565 | C |
| 9842NH.001000 | Chrome | Reel | 1,000 m | 8719605023223 | |
| 9842NH.002500 | Chrome | Reel | 2,500 m | 8719605023247 | |
| 9842NH.01305 | White | Reel | 305 m | 8719605023285 | |
| 9842NH.01500 | White | Reel | 500 m | 8719605184795 | |
| 9842NH.011000 | White | Reel | 1,000 m | 8719605023278 |