Description
Construction Details
Conductor
| Element | No. of Elements | Size | Stranding | Material |
|---|---|---|---|---|
| Pair(s) | 1 | 18 AWG | 41×34 | TC – Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Pair(s) | PP – Polypropylene | 0.010 in (0.25 mm) | 0.067 in (1.7 mm) | Black & White |
Outer Shield
| Material |
|---|
| No Shield |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter |
|---|---|---|
| PVC – Polyvinyl Chloride | 0.016 in (0.41 mm) | 0.166 in |
| Overall Cable Diameter (Nominal): | 0.166 in |
Electrical Characteristics
Electricals
| Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Characteristic Impedence | Max. Current |
|---|---|---|---|
| 7.06 Ohm/1000ft | 15.3 pF/ft (50.2 pF/m) | 39 Ohm | 5 Amps per Conductor at 25ºC |
Voltage
| UL Voltage Rating |
|---|
| 300 V |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|---|
| 80°C | -20°C To +80°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 0.660 in (16.8 mm) | 0.660 in |
| Max. Pull Tension: | 41 lbs (19 kg) |
| Bulk Cable Weight: | 16 lbs/1000ft |
Standards and Compliance
| Environmental Suitability: | Indoor |
| AWM Compliance: | AWM 2937 |
| European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
History
| Update and Revision: | Revision Number: 0.251 Revision Date: 02-15-2024 |
Part Numbers
Variants
| Item # | Color | Putup Type | Length | UPC |
|---|---|---|---|---|
| 9740MN 006100 | Blue, Light | Reel | 100 ft | 612825385578 |
| 9740MN 0061000 | Blue, Light | Reel | 1,000 ft | 612825385608 |
| 9740MN 008100 | Gray | Reel | 100 ft | 612825385585 |
| 9740MN 0081000 | Gray | Reel | 1,000 ft | 612825382713 |
| 9740MN 004100 | Yellow | Reel | 100 ft | 612825385561 |
| 9740MN 0041000 | Yellow | Reel | 1,000 ft | 612825385592 |