Product Overview
Suitable Applications: |
Instrumentation and computer cable; For EIA RS-232 data transmission applications |
Physical Characteristics (Overall)
AWG |
Stranding |
Material |
No. of Pairs |
24 |
7×32 |
TC – Tinned Copper |
3 |
Material |
Nominal Diameter |
Diameter +/- Tolerance |
PE – Polyethylene |
1.12 mm |
0.05 mm |
Number |
Color |
Pair 1 |
Black & Red |
Pair 2 |
Black & White |
Pair 3 |
Black & Green |
Type |
Material |
Material Trade Name |
Thickness of Foil |
Drainwire Material |
Drainwire AWG |
Tape |
Bi-Laminate (Alum+Poly) |
Beldfoil® |
9 / 12 µm |
TC – Tinned Copper |
AWG24/7 |
Material |
Nominal Diameter |
Nominal Wall Thickness |
LSZH – Low Smoke Zero Halogen (Flame Retardant) |
6.07 mm |
0.9 mm |
Construction and Dimensions
Description |
3 pairs twisted to cable core |
Electrical Characteristics
Nominal Conductor DCR |
Nominal Inner Shield DCR |
78.7 Ohm/km |
55.8 Ohm/km |
Nom. Capacitance Conductor to Conductor |
Nom. Capacitance Conductor to Other Conductor to Shield |
98.4 pF/m |
164 pF/m |
Frequency [MHz] |
Nominal Characteristic Impedance |
N/A |
75 Ohm |
Element |
Max. Recommended Current [A] |
Conductor(s) |
1.76 Amps per Conductor |
Temperature Range
Installation Temperature Range: |
-15°C To +80°C |
Storage Temperature Range: |
-45°C To +80°C |
Operating Temp Range (Flexible Install): |
-15°C To +80°C |
Operating Temp Range (Fixed Install): |
-45°C To +80°C |
Mechanical Characteristics
Oil Resistance: |
IEC 60811-404 |
Min. Bend Radius During Installation: |
60.7 mm |
Standards
CPR Euroclass: |
Cca-s1,d1,a1 |
CENELEC Compliance: |
EN 50290-2-20 |
Applicable Environmental and Other Programs
Environmental Space: |
Indoor – Euroclass Cca |
Suitability
Suitability – Indoor: |
Yes |
Suitability – Non-Halogenated: |
Yes |
Suitability – Sunlight Resistance: |
Yes |
Flammability, LS0H, Toxicity Testing
IEC Flammability: |
IEC 60332-1-2 |
IEC 60754-1 – Halogen Amount: |
Zero |
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: |
2.5 µS/mm |
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: |
4.3 |
IEC 61034-2 – Smoke Density Min. Transmittance: |
60% |
History
Update and Revision: |
Revision Number: 0.28 Revision Date: 12-22-2023 |