Description
Product Overview
Suitable Applications: | robotic, harsh environment, Allen Bradley Data Highway communication interface between PLC processors, I/O devices, operator interfaces, computers and other intelligent devices, PLC processor interlocking, peer-to-peer messaging, remote programming, troubleshooting, I/O updates, etc. |
Construction Details
Conductor
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Pair(s) | 1 | 20 AWG | 42×36 | TC – Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes |
---|---|---|---|---|---|
Pair(s) | PE – Polyethylene | 0.0185 in (0.470 mm) | 0.075 in (1.9 mm) | Clear & Blue | Twinax with rod fillers |
Outer Shield
Shield Type | Material | Coverage |
---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% |
Braid | Tinned Copper (TC) | 85% |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC – Polyvinyl Chloride | 0.033 in (0.84 mm) | 0.243 in (6.17 mm) |
Overall Cable Diameter (Nominal): | 0.243 in (6.17 mm) |
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Shield | Nom. Characteristic Impedence | Nom. Velocity of Prop. |
---|---|---|---|---|---|
Pair(s) | 9.5 Ohm/1000ft (31 Ohm/km) | 19.7 pF/ft (64.6 pF/m) | 37 pF/ft | 78 Ohm | 66% |
High Frequency (Nominal/Typical)
Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
---|---|---|
Pair(s) | 1 | 0.6 dB/100ft |
10 | 2.1 dB/100ft | |
50 | 5.0 dB/100ft | |
100 | 7.5 dB/100ft | |
200 | 11.0 dB/100ft | |
400 | 16.0 dB/100ft |
Voltage
UL Voltage Rating |
---|
300 V (CM, Cl2) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|---|
80°C | -40°C to 80°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
2.5 in (64 mm) | 2.5 in |
Max. Pull Tension: | 40 lbs (18 kg) |
Bulk Cable Weight: | 34 lbs/1000ft (51 kg/km) |
Standards and Compliance
Environmental Suitability: | Indoor |
Flammability / Reaction to Fire: | UL1685 UL Loading, IEC 60332-1-2 |
CPR Compliance: | CPR Euroclass: Eca |
NEC / UL Compliance: | Article 725, Article 800, CM, CL2 |
AWM Compliance: | AWM 2464 |
CEC / C(UL) Compliance: | CM |
European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
UK Regulation Compliance: | UKCA Mark |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
Other Standard Compliance(s): | P-7K-SC-182141-MSHA |
History
Update and Revision: | Revision Number: 0.290 Revision Date: 02-15-2024 |
Part Numbers
Variants
Item # | Color | UPC | Footnote |
---|---|---|---|
9463F J221000 | Strong Blue | 612825253716 | C |