9207NH – 100? Twinax, 1 Pr #20 Str-1c TC/1c BC, PE Jkt, Duofoil®+TC Braid, LSZH Jkt, IEC-60332-3C

Call for Price

Compare

Description

Product Overview

Suitable Applications: Twinaxial instrumentation and computer cable; For data transmission applications

Physical Characteristics (Overall)

Conductor
Element AWG Stranding Material No. of Conductors
Insulated Conductor(s) A 20 7×28 BC – Bare Copper 1
Insulated Conductor(s) B 20 7×28 TC – Tinned Copper 1
Conductor Count: 2
Total Number of Pairs: 1
Insulation
Element Material Nominal Diameter Diameter +/- Tolerance
Insulated Conductor(s) A PE – Polyethylene 2.11 mm 0.08 mm
Insulated Conductor(s) B PE – Polyethylene 2.11 mm 0.08 mm
Color Chart
Number Color
Insulated conductor A Clear
Insulated conductor B Clear
Outer Shield
Type Material Material Trade Name Coverage [%] Thickness of Foil
Tape Tri-Laminate (Alum+Poly+Alum) Duofoil® 85% 9 / 23 / 9 µm
Braid Tinned Copper (TC) 85%
Outer Jacket
Material Nominal Diameter Nominal Wall Thickness
LSZH – Low Smoke Zero Halogen (Flame Retardant) 8.6 mm 0.89 mm

Construction and Dimensions

Cabling
Description
2 wires twisted to cable core

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR Nominal Outer Shield DCR
31.2 Ohm/km 6.6 Ohm/km
Capacitance
Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Shield
47.6 pF/m 75.5 pF/m
Inductance
Nominal Inductance
0.51 µH/m
Impedance
Nominal Characteristic Impedance
100 Ohm
High Frequency (Nominal/Typical)
Frequency [MHz] Nom. Insertion Loss
1 MHz 0.98 dB/100m
10 MHz 3.94 dB/100m
50 MHz 9.19 dB/100m
100 MHz 13.45 dB/100m
200 MHz 21 dB/100m
400 MHz 33.46 dB/100m
Delay
Nominal Delay Nominal Velocity of Propagation (VP) [%]
510 ns/ft 66%
Voltage
Voltage Rating [V]
300 V

Temperature Range

Installation Temperature Range: -15°C To +80°C
Storage Temperature Range: -45°C To +80°C
Operating Temp Range (Flexible Install): -15°C To +80°C
Operating Temp Range (Fixed Install): -45°C To +80°C

Mechanical Characteristics

Oil Resistance: ASTMD741
Min. Bend Radius During Installation: 86 mm

Standards

CPR Euroclass: Eca

Applicable Environmental and Other Programs

Environmental Space: Indoor – Euroclass Eca

Flammability, LS0H, Toxicity Testing

IEC Flammability: IEC 60332-1-2, IEC 60332-3-24
IEC 60754-1 – Halogen Amount: Zero
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: 2.5 µS/mm
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: 4.3

Related Part Numbers

Variants
Item # Color Put-Up Type Length EAN
9207NH.00100 Black Reel 100 m 8719605020222
9207NH.00152 Black Reel 152 m 8719605020246
9207NH.00305 Black Reel 305 m 8719605020253
9207NH.00500 Black Reel 500 m 8719605020260
9207NH.001000 Black Reel 1,000 m 8719605020239
9207NH.01250 Gray Reel 250 m 8719605020284
9207NH.011000 Gray Reel 1,000 m 8719605020277

History

Update and Revision: Revision Number: 0.248 Revision Date: 02-15-2024