Physical Characteristics (Overall)
AWG |
Stranding |
Material |
Nominal Diameter |
No. of Coax |
18 |
Solid |
BCCS – Bare Copper Covered Steel |
0.04 in |
1 |
Material |
Nominal Diameter |
PE – Polyethylene (Foam) |
0.18 in |
Table Notes: |
Gas Injected |
Type |
Layer |
Material |
Material Trade Name |
Coverage [%] |
Tape |
1 |
Tri-Laminate (Alum+Poly+Alum) |
Duofoil® |
100% |
Braid |
2 |
Aluminum |
|
60% |
Tape |
3 |
Tri-Laminate (Alum+Poly+Alum) |
Duofoil® |
100% |
Material |
Nominal Diameter |
PVC – Polyvinyl Chloride |
0.275 in |
Electrical Characteristics
Nominal Conductor DCR |
Nominal Outer Shield DCR |
Outer Conductor DCR |
28 Ohm/1000ft |
6.5 Ohm/1000ft |
6.5 Ohm/1000ft |
Nom. Capacitance Conductor to Shield |
16.2 pF/ft |
Nominal Inductance |
0.097 µH/ft |
Nominal Characteristic Impedance |
75 Ohm |
Frequency [MHz] |
Min. Structural Return Loss (SRL) |
5-1000 MHz |
20 dB |
Nominal Delay |
Nominal Velocity of Propagation (VP) [%] |
1.2 ns/ft |
83% |
Frequency [MHz] |
Max. Insertion Loss (Attenuation) |
5 MHz |
0.58 dB/100ft |
55 MHz |
1.60 dB/100ft |
211 MHz |
3.05 dB/100ft |
270 MHz |
3.37 dB/100ft |
300 MHz |
3.55 dB/100ft |
350 MHz |
3.85 dB/100ft |
400 MHz |
4.15 dB/100ft |
450 MHz |
4.40 dB/100ft |
550 MHz |
4.90 dB/100ft |
750 MHz |
5.65 dB/100ft |
870 MHz |
6.11 dB/100ft |
1000 MHz |
6.55 dB/100ft |
UL Voltage Rating |
350 V RMS |
Temperature Range
Operating Temperature Range: |
-40°C To +80°C |
Mechanical Characteristics
Bulk Cable Weight: |
27 lbs/1000ft |
Max. Pull Tension: |
126 lbs |
Min. Bend Radius/Minor Axis: |
2.75 in |
Standards
NEC/(UL) Compliance: |
CATV, CM |
Applicable Environmental and Other Programs
Environmental Space: |
Indoor (Not Riser or Plenum) |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2003/96/EC (BFR): |
Yes |
EU Directive 2011/65/EU (RoHS 2): |
Yes |
EU Directive 2012/19/EU (WEEE): |
Yes |
EU Directive 2015/863/EU (RoHS 2 amendment): |
Yes |
EU Directive Compliance: |
EU Directive 2003/11/EC (BFR) |
MII Order #39 (China RoHS): |
Yes |
Suitability
Suitability – Indoor: |
Yes |
Flammability, LS0H, Toxicity Testing
UL Flammability: |
UL1685 UL Loading |
IEC Flammability: |
IEC 60332-1-2 |
UL voltage rating: |
350 V RMS |
Plenum/Non-Plenum
Related Part Numbers
Item # |
Color |
Put-Up Type |
Length |
UPC |
9118 0101000 |
Black |
Reel |
1,000 ft |
612825224631 |
9118 010U1000 |
Black |
UnReel |
1,000 ft |
612825224600 |
9118 0081000 |
Gray |
Reel |
1,000 ft |
612825224624 |
9118 009U1000 |
White |
UnReel |
1,000 ft |
612825224648 |
9118 Q5HU1000 |
White, Neutral |
UnReel |
1,000 ft |
612825224655 |
Footnote: |
C – CRATE REEL PUT-UP., Z – FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. |
History
Update and Revision: |
Revision Number: 0.425 Revision Date: 04-14-2023 |