9058 – CATV Video, RG6, 18 AWG BCCS, Tri Shield, CM PVC Jacket

Call for Price

Compare
SKU: 9058 Categories: , , ,

Description

Physical Characteristics (Overall)

Conductor
AWG Stranding Material Nominal Diameter No. of Coax
18 Solid BCCS – Bare Copper Covered Steel 0.04 in 1
Conductor Count: 1
Insulation
Material Nominal Diameter
PE – Polyethylene (Foam) 0.18 in
Table Notes: Gas Injected
Outer Shield
Type Layer Material Material Trade Name Coverage [%]
Tape 1 Tri-Laminate (Alum+Poly+Alum) Duofoil® 100%
Braid 2 Aluminum 75%
Tape 3 Bi-Laminate (Alum+Poly) 100%
Table Notes: Tape has shorting fold and is bonded to jacket
Outer Jacket
Material Nominal Diameter
PVC – Polyvinyl Chloride 0.275 in

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR Nominal Outer Shield DCR Outer Conductor DCR
28 Ohm/1000ft 5.6 Ohm/1000ft 5.6 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to Shield
16.2 pF/ft
Inductance
Nominal Inductance
0.097 µH/ft
Impedance
Nominal Characteristic Impedance
75 Ohm
Return Loss (RL)
Frequency [MHz] Min. Structural Return Loss (SRL)
5-1000 MHz 20 dB
Delay
Nominal Delay Nominal Velocity of Propagation (VP) [%]
1.2 ns/ft 83%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation)
5 MHz 0.58 dB/100ft
55 MHz 1.60 dB/100ft
211 MHz 3.05 dB/100ft
270 MHz 3.37 dB/100ft
300 MHz 3.55 dB/100ft
350 MHz 3.85 dB/100ft
400 MHz 4.15 dB/100ft
450 MHz 4.40 dB/100ft
550 MHz 4.90 dB/100ft
750 MHz 5.65 dB/100ft
870 MHz 6.11 dB/100ft
1000 MHz 6.55 dB/100ft
Voltage
UL Voltage Rating
350 V RMS

Temperature Range

Non-UL Temp Rating: 80°C
Operating Temperature Range: -40°C To +80°C

Mechanical Characteristics

Bulk Cable Weight: 28 lbs/1000ft
Max. Pull Tension: 138 lbs
Min. Bend Radius/Minor Axis: 2.75 in

Standards

NEC/(UL) Compliance: CATV, CM
CEC/C(UL) Compliance: CM
RG Type: 6
Series Type: 6

Applicable Environmental and Other Programs

Environmental Space: Indoor (Not Riser or Plenum)
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: Yes
MII Order #39 (China RoHS): Yes

Suitability

Suitability – Indoor: Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: UL1685 UL Loading
UL voltage rating: 350 V RMS

Plenum/Non-Plenum

Plenum (Y/N): No

Related Part Numbers

Variants
Item # Color Put-Up Type Length UPC
9058 0101000 Black Reel 1,000 ft 612825224075
9058 010U1000 Black UnReel 1,000 ft 612825396192
9058 009U1000 White UnReel 1,000 ft 612825224082

History

Update and Revision: Revision Number: 0.374 Revision Date: 04-14-2023