Product Overview
Suitable Applications: |
Audio, Control & Instrumentation cable; For data transmission applications |
Physical Characteristics (Overall)
AWG |
Stranding |
Material |
No. of Conductors |
18 |
16×30 |
TC – Tinned Copper |
3 |
Material |
Nominal Diameter |
Diameter +/- Tolerance |
Nominal Wall Thickness |
PE – Polyethylene |
2.08 mm |
0.05 mm |
0.018 in |
Number |
Color |
Wire 1 |
Black |
Wire 2 |
Red |
Wire 3 |
Clear |
Type |
Material |
Material Trade Name |
Coverage [%] |
Thickness of Foil |
Drainwire Material |
Drainwire AWG |
Drainwire Construction n x D |
Tape |
Bi-Laminate (Alum+Poly) |
Beldfoil® (Z-Fold®) |
100% |
9 / 12 µm |
TC – Tinned Copper |
AWG20/7 |
Stranded |
Material |
Nominal Diameter |
Nominal Wall Thickness |
LSZH – Low Smoke Zero Halogen (Flame Retardant) |
6.25 mm |
0.84 mm |
Construction and Dimensions
Description |
Twists |
3 wires twisted to cable core |
8 twist/ft |
Electrical Characteristics
Nominal Conductor DCR |
Nominal Outer Shield DCR |
21.7 Ohm/km |
27.9 Ohm/km |
Nom. Capacitance Conductor to Conductor |
Nom. Capacitance Conductor to Other Conductor to Shield |
78.7 pF/m |
157.5 pF/m |
Nominal Inductance |
0.605 µH/m |
Nominal Characteristic Impedance |
69 Ohm |
Nominal Velocity of Propagation (VP) [%] |
66% |
Element |
Max. Recommended Current [A] |
Conductor(s) |
5.3 Amps per Conductor |
Temperature Range
Installation Temperature Range: |
-15°C To +80°C |
Storage Temperature Range: |
-45°C To +80°C |
Operating Temp Range (Flexible Install): |
-15°C To +80°C |
Operating Temp Range (Fixed Install): |
-45°C To +80°C |
Mechanical Characteristics
Oil Resistance: |
IEC 60811-404 |
Min. Bend Radius During Installation: |
62.5 mm |
Min. Bend Radius/Minor Axis: |
2.5 in |
Standards
CPR Euroclass: |
Cca-s1,d1,a1 |
CENELEC Compliance: |
EN 50290-2-20 |
Applicable Environmental and Other Programs
Environmental Space: |
Indoor – Euroclass Cca |
EU Directive Compliance: |
EU Directive 2003/11/EC (BFR) |
MII Order #39 (China RoHS): |
Yes |
Suitability
Suitability – Indoor: |
Yes |
Suitability – Non-Halogenated: |
Yes |
Suitability – Sunlight Resistance: |
Yes |
Flammability, LS0H, Toxicity Testing
IEC Flammability: |
IEC 60332-1-2 |
IEC 60754-1 – Halogen Amount: |
Zero |
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: |
2.5 µS/mm |
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: |
4.3 |
IEC 61034-2 – Smoke Density Min. Transmittance: |
60% |
Plenum/Non-Plenum
History