7965GLY – Category 6 Cable, 4 Pair, U/UTP, LSZH Indoor CPR Dca

Call for Price

Compare

Description

Product Overview

Suitable Applications: Horizontal and building backbone cable; Support current and future Category 6 and 5e applications, such as: 1000Base – T (Gigabit Ethernet), 100 Base – T, 10 Base – T, FDDI, ATM

Construction Details

Conductor
Element Size Stranding Material No. of Pairs No. of Elements
Individual Pair 24 AWG Solid BC – Bare Copper 4 8
Insulation
Element Material Nom. Insulation Diameter Color Code
Individual Pair PE – Polyethylene 0.90 mm (0.035 in) White/Blue & Blue, White/Green & Green, White/Orange & Orange, White/Brown & Brown
Cable Core
Description Separator
4 pairs twisted together Center Member (Patented X-Spline®)
Outer Jacket
Material Nom. Diameter
LSZH – Low Smoke Zero Halogen (Flame Retardant) 5.3 mm (0.21 in)
Overall Cable Diameter (Nominal): 5.3 mm (0.21 in)

Electrical Characteristics

Electricals
Max. Conductor DCR Max. Mutual Capacitance Max. Capacitance Unbalance Nom. Characteristic Impedance
95 Ohm/km (29 Ohm/1000ft) 56 pF/m (17 pF/ft) 160 pF/100m 100 Ohm
Delay
Max. Delay Skew Nom. Velocity of Prop.
40 ns/100m 70%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) [dB/100m] Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Min. TCL [dB] Min. ELTCTL [dB]
1 2.1 75.3 72.3 73.2 70.2 70 67 20 40 35
4 3.8 66.3 63.3 62.4 59.4 58 55 23 34 23
10 6 60.3 57.3 54.3 51.3 50 47 25 30 15
16 7.6 57.2 54.2 49.6 46.6 45.9 42.9 25 28 10.9
20 8.5 55.8 52.8 47.3 44.3 44 41 25 27 9
31.2 10.7 52.9 49.9 42.1 39.1 40.1 37.1 23.6 25.1 5.1
62.5 15.5 48.4 54.4 32.9 29.9 34.1 31.1 21.5 22
100 19.9 45.3 42.3 25.4 22.4 30 27 20.1 20
155 25.3 42.4 39.4 17.1 14.1 26.2 23.2 18.8 18.1
200 29.1 40.8 37.8 11.6 8.6 24 21 18 17
250 33 39.3 36.3 6.3 3.3 22 19 17.3 16
Table Notes: Limits below 4 MHz are for information only.
Reference standard: IEC 61156-5
Screening Class: Type III
Table Notes: Coupling Attenuation
Voltage
Voltage Rating
72 V DC

Mechanical Characteristics

Temperature
Operating
-30°C To +60°C
Bend Radius
Stationary Min. Installation Min.
23 mm (0.91 in) 46 mm (1.8 in)
Max. Pull Tension: 80 N (18 lbf)
Bulk Cable Weight: 32 kg/km (22 lbs/1000ft)

Standards and Compliance

Environmental Suitability: Indoor – Euroclass Dca
Flammability / Reaction to Fire: IEC 60332-1-2
CPR Compliance: CPR Euroclass: Dca-s2,d2,a1
IEEE Compliance: PoE: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Data Category: Category 6
TIA/EIA Compliance: ANSI/TIA 568.2-D
ISO/IEC Compliance: ISO/IEC 11801-1, IEC 61034-2 – Smoke Density Min Transmittance = 60%
CENELEC Compliance: EN 50173-1, Segregation class according EN50174-2 = a
European Halogen Free Standards: IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 – Halogen Amount = Zero, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 2.5 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3
European Directive Compliance: EU CE Mark
UK Regulation Compliance: UKCA Mark

Product Notes

Notes: Electrical values are expected performance based on cable testing and representative performance within a typical Belden system.

History

Update and Revision: Revision Number: 0.17 Revision Date: 12-12-2023

Part Numbers

Variants
Item # Color Putup Type Length EAN
7965GLY.00500 Blue Reel 500 m 8719605198518