Physical Characteristics (Overall)
AWG |
Stranding |
Material |
Nominal Diameter |
No. of Coax |
10 |
Solid |
BCCA – Bare Copper Covered Aluminum |
0.108 in |
1 |
Material |
Nominal Diameter |
PE – Polyethylene (Foam) |
0.285 in |
Table Notes: |
Gas Injected |
Type |
Layer |
Material |
Material Trade Name |
Coverage [%] |
Tape |
1 |
Tri-Laminate (Alum+Poly+Alum) |
Duofoil® |
100% |
Braid |
2 |
Tinned Copper (TC) |
|
95% |
Table Notes: |
PO – Polyolefin |
Material |
Nominal Diameter |
PE – Polyethylene |
0.403 in |
Electrical Characteristics
Nominal Conductor DCR |
Nominal Conductor DCR Conductor Resistance |
Nominal Outer Shield DCR |
Outer Conductor DCR |
1.34 Ohm/1000ft |
1.34 Ohm/1000ft |
2 Ohm/1000ft |
2 Ohm/1000ft |
Nom. Capacitance Conductor to Shield |
23 pF/ft |
Nominal Inductance |
0.06 µH/ft |
Nominal Characteristic Impedance |
50 Ohm |
Table Notes: |
51.0 +/- 2.0 Ohms |
High Frequency (Nominal/Typical)
Frequency [MHz] |
Nom. Insertion Loss |
30 MHz |
0.7 dB/100ft |
50 MHz |
0.9 dB/100ft |
150 MHz |
1.5 dB/100ft |
220 MHz |
1.8 dB/100ft |
450 MHz |
2.7 dB/100ft |
900 MHz |
3.8 dB/100ft |
1500 MHz |
5.1 dB/100ft |
1800 MHz |
5.6 dB/100ft |
2000 MHz |
6 dB/100ft |
2500 MHz |
6.7 dB/100ft |
3000 MHz |
7.5 dB/100ft |
3500 MHz |
8.2 dB/100ft |
4500 MHz |
9.5 dB/100ft |
5800 MHz |
11.1 dB/100ft |
6000 MHz |
11.4 dB/100ft |
Nominal Delay |
Nominal Velocity of Propagation (VP) [%] |
1.17 ns/ft |
86% |
Frequency [MHz] |
Max. Power Rating [W] |
30 MHz |
3,427 W |
50 MHz |
2,588 W |
150 MHz |
1,428 W |
220 MHz |
1,195 W |
450 MHz |
817 W |
900 MHz |
575 W |
1,500 MHz |
437 W |
2,000 MHz |
375 W |
2,500 MHz |
334 W |
3,500 MHz |
282 W |
4,500 MHz |
247 W |
6,000 MHz |
213 W |
4,500 MHz |
247 W |
5,800 MHz |
217 W |
6,000 MHz |
213 W |
Non-UL Voltage Rating |
300 V RMS |
Frequency [MHz] |
Max. VSWR |
5-6000 MHz |
1.25:1 |
Temperature Range
Operating Temperature Range: |
-40°C To +75°C |
Mechanical Characteristics
Bulk Cable Weight: |
73 lbs/1000ft |
Max. Pull Tension: |
150 lbs |
Min. Bend Radius/Minor Axis: |
4 in |
Standards
Applicable Environmental and Other Programs
Environmental Space: |
Water Exposure/Below-Grade Conduit |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
EU Directive 2011/65/EU (RoHS 2): |
Yes |
EU Directive 2012/19/EU (WEEE): |
Yes |
EU Directive 2015/863/EU (RoHS 2 amendment): |
Yes |
EU Directive Compliance: |
EU Directive 2003/11/EC (BFR) |
MII Order #39 (China RoHS): |
Yes |
Suitability
Suitability – Aerial: |
Yes – When supported by messenger wire |
Suitability – Burial: |
Yes |
Suitability – Indoor: |
Yes |
Suitability – Outdoor: |
Yes |
Plenum/Non-Plenum
Related Part Numbers
Item # |
Color |
Put-Up Type |
Length |
UPC |
7810WB 010500 |
Black |
Reel |
500 ft |
612825189893 |
7810WB 0101000 |
Black |
Reel |
1,000 ft |
612825189848 |
Footnote: |
C – CRATE REEL PUT-UP. |
History
Update and Revision: |