Description
Product Overview
Suitable Applications: | Analog Video; Interconnect camera to CCU (camera control unit) |
Construction Details
Series Type: | Triax 8/11/14 |
Conductor
No. of Elements | Size | Stranding | Nom. Diameter | Material |
---|---|---|---|---|
1 | 12 AWG | Stranded | 2.2 mm | BC – Bare Copper |
Insulation
Element | Material | Nom. Insulation Diameter |
---|---|---|
Insulated Conductor | PE – Polyethylene (Foam) | 9.7 mm (0.38 in) |
Inner Shield
Shield Type | Material | Coverage |
---|---|---|
Braid | Bare Copper (BC) | 80% |
Inner Jacket
Material | Nom. Diameter |
---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 11.9 mm (0.469 in) |
Outer Shield
Outer Shield Type | Material | Coverage |
---|---|---|
Braid | Bare Copper (BC) | 80% |
Outer Jacket
Material | Nom. Diameter |
---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 14.5 mm |
Electrical Characteristics
Attenuation
Frequency | Nom. Attenuation |
---|---|
1 MHz | 0.4 dB/100m |
10 MHz | 1.3 dB/100m |
20 MHz | 1.7 dB/100m |
40 MHz | 2.5 dB/100m |
50 MHz | 2.8 dB/100m |
60 MHz | 3.1 dB/100m |
100 MHz | 4.2 dB/100m |
270 MHz | 7 dB/100m |
300 MHz | 7.6 dB/100m |
540 MHz | 10.1 dB/100m |
1000 MHz | 14.3 dB/100m |
Electricals
Nom. Conductor DCR | Nom. Inner Shield DCR | Nom. Outer Shield DCR | Nom. Capacitance Cond-to-Shield |
Nom. Characteristic Impedance | Nom. Velocity of Prop. |
---|---|---|---|---|---|
5.7 Ohm/km | 6.4 Ohm/km (2.0 Ohm/1000ft) | 4.1 Ohm/km (1.2 Ohm/1000ft) | 55 pF/m (17 pF/ft) | 75 Ohm | 81% |
Screening
Frequency | Min. Screening Attenuation |
---|---|
30 – 850 MHz | 75 dB |
Mechanical Characteristics
Temperature
Operating | Installation | Storage |
---|---|---|
-30°C To +70°C | -5°C To +70°C | -30°C To +70°C |
Bend Radius
Stationary Min. |
---|
150 mm (5.9 in) |
Max. Pull Tension: | 550 N (120 lbf) |
Standards and Compliance
Environmental Suitability: | Indoor – Euroclass Eca |
Flammability / Reaction to Fire: | IEC 60332-1-2, IEC 60332-3-24, CEI 20-22-3 |
CPR Compliance: | CPR Euroclass: Eca |
ISO/IEC Compliance: | IEC 61034-2 – Smoke Density Min Transmittance = 60% |
European Halogen Free Standards: | IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 – Halogen Amount = Zero, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 2.5 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3 |
European Directive Compliance: | EU CE Mark |
UK Regulation Compliance: | UKCA Mark |
History
Update and Revision: | Revision Number: 0.219 Revision Date: 12-19-2022 |
Part Numbers
Variants
Item # | Color | Putup Type | Length | EAN |
---|---|---|---|---|
7785ECH.01500 | Red | Reel | 500 m | 8719605014719 |
7785ECH.012000 | Red | Reel | 2,000 m | 8719605124777 |