Product Overview
Suitable Applications: |
High Flex applications |
Physical Characteristics (Overall)
AWG |
Stranding |
Material |
No. of Conductors |
22 |
Stranded |
TC – Tinned Copper |
4 |
Material |
Nominal Diameter |
Diameter +/- Tolerance |
PO – Polyolefin |
1.4 mm |
0.2 mm |
Color |
White & Yellow & Blue & Orange |
Material |
TPE – Thermoplastic Elastomer |
Filler |
Number of Fillers |
Yes |
5 |
Type |
Material |
Coverage [%] |
Tape |
Bi-Laminate (Alum+Poly) |
90% |
Braid |
Tinned Copper (TC) |
|
Material |
Nominal Diameter |
Diameter +/- Tolerance |
PUR – Polyurethane |
7.1 mm |
0.2 mm |
Construction and Dimensions
Min Elongation at Breakof Insulation: |
150 % |
Min Elongation at Breakof InsulAged: |
70 % |
Min Tensile Strength of Insulation Aged: |
70 % |
Min Tensile Strength at Breakof Insul: |
20.7 MPa |
Min Elongation at Breakof Jacket: |
100 % |
Min Tensile Strength of Jacket: |
10.3 MPa |
Min Tensile Strength of Jacket Aged: |
70 % |
Min Elongation at Break of Jacket Aged: |
65 % |
Electrical Characteristics
Max. Conductor DCR |
59.4 Ohm/km |
Nominal Characteristic Impedance |
100 Ohm |
Max. Delay Skew |
20 ns/100m |
Temperature Range
Operating Temperature Range: |
-20°C To +80°C |
Mechanical Characteristics
Bending Test: |
Reverse bending test at bending radius 7D, weight 300 g, Speed 60 cycles/min : ? 1 million |
Torsion Test: Min Number of Torsions: |
5000000 |
Torsion Test: Description: |
Stress : +/- 180°, weight : 300g, s=30 cycles/min, torsion length : 1000 mm |
Flexibility Test: |
At 113°C x 168hrs: No cracking (for Insulation & Jacket) |
Deformation Test for Insulation: |
?50 % |
Deformation Test for Jacket: |
?50 % |
IRM 902 Mineral Oil Resistance Test: |
At (100°Cx96hrs) – Tensile Strength of Jacket : ? 50% of original and Elongation of jacket : ? 50% of original |
Min No. of Drag Chain Cycles: |
? 5 million |
Drag Chain Parameters: |
r=15 D, a= 10m/s^2, v= 180m/min, chain length : 5 m |
Standards
UL AWM Style Compliance: |
AWM 20549 |
ISO/IEC Compliance: |
ISO/IEC 11801-1, IEC 61156-6 |
Data Category: |
Category 5e |
Applicable Environmental and Other Programs
Environmental Space: |
Indoor |
Suitability
Suitability – Indoor: |
Yes |
Suitability – Oil Resistance: |
Yes |
Flammability, LS0H, Toxicity Testing
IEC 60754-1 – Halogen Amount: |
HCl + HBr : According to EN60754-1 :?0.5 %,
HF : According to EN 60684-2 : ?0.1 % |
History
Update and Revision: |
Revision Number: 0.19 Revision Date: 03-18-2024 |