Description
Product Overview
Suitable Applications: | Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, …),low voltage digital control (24v, ), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners |
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter |
---|---|---|---|
18 | 7×26 | BC – Bare Copper | 0.045 in |
Conductor Count: | 18 |
Total Number of Triads: | 2 |
Insulation
Material | Nominal Diameter |
---|---|
PVC/Nylon – Polyvinyl Chloride + Nylon | 0.088 in |
Color Chart
Number | Color |
---|---|
Triad 1 | Black, White and Red Numbered 1 |
Triad 2 | Black, White and Red Numbered 2 |
Inner Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG |
---|---|---|---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC – Tinned Copper | 0.029 in | 22 |
Outer Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG |
---|---|---|---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC – Tinned Copper | 0.029 in | 22 |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|---|---|
PVC – Polyvinyl Chloride | 0.470 in | 0.047 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR |
---|
5.86 Ohm/1000ft |
Current
Max. Recommended Current [A] |
---|
4.8 Amps per Conductor at 30ºC |
Temperature Range
UL Temp Rating: | 90°C Dry/75°C Wet |
Operating Temperature Range: | -25°C To +90°C |
Mechanical Characteristics
Bulk Cable Weight: | 252 lbs/1000ft |
Max. Pull Tension: | 134 lbs |
Min Bend Radius (Overall): | 4.75 in |
Standards
NEC Articles: | Article 336 |
NEC/(UL) Compliance: | NPLF, TC-ER |
IEEE Compliance: | 1202 |
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2011/65/EU (RoHS 2): | Yes |
EU Directive 2012/19/EU (WEEE): | Yes |
EU Directive 2015/863/EU (RoHS 2 amendment): | Yes |
EU Directive Compliance: | EU Directive 2003/11/EC (BFR) |
EU CE Mark: | Yes |
CA Prop 65: | Yes |
Suitability
Suitability – Indoor: | Yes |
Suitability – Outdoor: | Yes |
Suitability – Sunlight Resistance: | Yes |
Flammability, LS0H, Toxicity Testing
CSA/C(UL) Flammability: | FT4 |
UL voltage rating: | 600 V RMS (Type TC) |
Related Part Numbers
Variants
Item # | Put-Up Type |
---|---|
62T1806 0105500 | Reel |
History
Update and Revision: | Revision Number: 0.43 Revision Date: 01-11-2024 |