Welcome to American Tele Data

USA MADE - BABA COMPLIANT

AMERICAN TELEDATA

855 - 848 - Data

855 - 40 - Fiber

558AMS – Access Control, 16c (#22-3pr, #18-4c, #22-6c), Only Card Reader Pairs Shielded, Banana Peel®, CMR

Call for Price

Description

Product Overview

Suitable Applications: Access Control, Security System, Power Limited Controls
Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.

Construction Details

Conductor
Element Description Element No. of Elements Size Stranding Material
Card Reader Pair(s) 3 22 AWG 7×30 BC – Bare Copper
Door Contact Conductor(s) 2 22 AWG 7×30 BC – Bare Copper
REX/Spare Conductor(s) 4 22 AWG 7×30 BC – Bare Copper
Lock Power Conductor(s) 4 18 AWG 7×26 BC – Bare Copper
Insulation
Element Description Element Material Color Code
Card Reader Pair(s) PP – Polypropylene Black & Red, White & Green, Brown & Orange
Door Contact Conductor(s) PP – Polypropylene Black, Red
REX/Spare Conductor(s) PP – Polypropylene Black, Red, White, Green
Lock Power Conductor(s) PP – Polypropylene
Inner Shield
Element Description Element Shield Type Material Coverage Drainwire Type
Card Reader Pair(s) Tape Bi-Laminate (Alum+Poly) 100% 24 AWG (7×32) TC
Door Contact Conductor(s) No Shield
REX/Spare Conductor(s) No Shield
Lock Power Conductor(s) No Shield
Inner Jacket
Element Description Element Material Nom. Diameter Ripcord Color
Card Reader Pair(s) PVC – Polyvinyl Chloride 0.211 in (5.36 mm) Yes Orange
Door Contact Conductor(s) PVC – Polyvinyl Chloride 0.123 in (3.12 mm) Yes White
REX/Spare Conductor(s) PVC – Polyvinyl Chloride 0.141 in (3.58 mm) Yes Blue
Lock Power Conductor(s) PVC – Polyvinyl Chloride 0.184 in (4.67 mm) Yes Gray
Outer Jacket
Nom. Diameter
0.399 in (10.1 mm)
Overall Cable Diameter (Nominal): 0.399 in (10.1 mm)

Electrical Characteristics

Electricals
Element Description Element Nom. Conductor DCR Nom. Inner Shield DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Shield Max. Current
Card Reader Pair(s) 16.3 Ohm/1000ft (53.5 Ohm/km) 14.9 Ohm/1000ft (48.9 Ohm/km) 24 pF/ft (79 pF/m) 43.25 pF/ft (141.9 pF/m) 2 Amps per Conductor at 25ºC
Door Contact Conductor(s) 16.4 Ohm/1000ft (53.8 Ohm/km) 17 pF/ft (56 pF/m) 2.2 Amps per Conductor at 25ºC
REX/Spare Conductor(s) 16.4 Ohm/1000ft (53.8 Ohm/km) 17 pF/ft (56 pF/m) 2.2 Amps per Conductor at 25ºC
Lock Power Conductor(s) 6.5 Ohm/1000ft (21 Ohm/km) 22 pF/ft (72 pF/m) 4 Amps per Conductor at 25ºC
Voltage
UL Voltage Rating
300 V (UL CMR)

Mechanical Characteristics

Temperature
Operating
0°C to +75°C
Max. Pull Tension: 200 lbs (91 kg)
Bulk Cable Weight: 80 lbs/1000ft (120 kg/km)

Standards and Compliance

Environmental Suitability: Indoor – Riser, Indoor
Flammability / Reaction to Fire: UL1666 Riser
NEC / UL Compliance: Article 800, CMR
CEC / C(UL) Compliance: CMR
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC Compliance: China RoHS II (GB/T 26572-2011)
Plenum Number: 658AMS

Product Notes

Notes: Cold environment installation: When installing cables that have been stored at ambient temperatures of 32 degrees Fahrenheit (0 degrees Centigrade) or lower, Belden recommends conditioning of the cable for 12 hours at room temperature prior to individual cable leg separation.