Product Overview
| Suitable Applications: |
Surveillance, CCTV Camera, PTZ (Pan-Tilt-Zoom) |
Physical Characteristics (Overall)
| Element |
AWG |
Stranding |
Material |
Nominal Diameter |
No. of Conductors |
No. of Coax |
| Coax(es) |
20 |
Solid |
BC – Bare Copper |
0.032 in |
|
1 |
| Pair1 |
18 |
19×30 |
BC – Bare Copper |
0.044 in |
2 |
|
| Pair2 |
18 |
7×26 |
BC – Bare Copper |
0.047 in |
2 |
|
| Element |
Material |
Nominal Diameter |
Nominal Wall Thickness |
| Coax(es) |
PE – Polyethylene (Foam) |
0.145 in |
|
| Pair1 |
PP – Polypropylene |
0.08 in |
|
| Pair2 |
PP – Polypropylene |
|
0.0065 in |
| Table Notes: |
Gas Injected |
| Number |
Color |
| Coax Core |
White |
| Pair1 |
Blue & White/Blue |
| Pair2 |
Black & Red |
| Element |
Type |
Material |
Material Trade Name |
Coverage [%] |
| Coax(es) |
Braid |
Bare Copper (BC) |
|
95% |
| Pair1 |
Tape |
Bi-Laminate (Alum+Poly) |
Beldfoil® |
100% |
| Pair2 |
No Shield |
|
|
|
| Material |
Nominal Diameter |
Nominal Wall Thickness |
| PVC – Polyvinyl Chloride |
0.227 in |
0.030 in |
| PVC – Polyvinyl Chloride |
0.219 in |
0.028 in |
| PVC – Polyvinyl Chloride |
0.158 in |
0.020 in |
| Drainwire Construction n x D |
| 7×28 |
| Material |
Nominal Diameter |
| Banana Peel (No Overall Jacket) |
0.451 in |
|
0.219 in |
|
0.158 in |
|
0.451 in |
Electrical Characteristics
| Element |
Nominal Conductor DCR |
Nominal Conductor DCR Conductor Resistance |
Nominal Inner Shield DCR |
| Coax(es) |
10 Ohm/1000ft |
10 Ohm/1000ft |
3.5 Ohm/1000ft |
| Pair1 |
6.5 Ohm/1000ft |
6.5 Ohm/1000ft |
|
| Pair2 |
6.5 Ohm/1000ft |
6.5 Ohm/1000ft |
|
| Element |
Nom. Capacitance Conductor to Conductor |
Nom. Capacitance Conductor to Shield |
| Coax(es) |
|
16.3 pF/ft |
| Pair1 |
26 pF/ft |
44 pF/ft |
| Pair2 |
21.5 pF/ft |
|
| Element |
Nominal Characteristic Impedance |
| Coax(es) |
75 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] |
Nom. Insertion Loss |
| 1 MHz |
0.3 dB/100ft |
| 5 MHz |
0.65 dB/100ft |
| 10 MHz |
0.9 dB/100ft |
| 50 MHz |
1.9 dB/100ft |
| 100 MHz |
2.6 dB/100ft |
| 200 MHz |
3.6 dB/100ft |
| 400 MHz |
5 dB/100ft |
| 700 MHz |
7 dB/100ft |
| 900 MHz |
8 dB/100ft |
| 1000 MHz |
8.5 dB/100ft |
| Element |
Max. Delay Skew |
Nominal Delay |
Nominal Velocity of Propagation (VP) [%] |
| Coax(es) |
83 ns/100m |
1.22 ns/ft |
83% |
| Element |
Max. Recommended Current [A] |
| Coax(es) |
|
| Pair1 |
5 Amps per Conductor at 25ºC |
| Pair2 |
|
| UL Voltage Rating |
| 300 V RMS |
Temperature Range
| Installation Temperature Range: |
0°C To +75°C |
| Operating Temperature Range: |
-10°C To +75°C |
| Separation Temp Range: |
0°C To +75°C |
Mechanical Characteristics
| Bulk Cable Weight: |
74 lbs/1000ft |
| Max. Pull Tension: |
140 lbs |
Standards
| NEC Articles: |
Article 800 |
| Other Specification: |
Video coax: RG 59/U |
Applicable Environmental and Other Programs
| Environmental Space: |
Indoor – Riser |
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2003/11/EC (BFR): |
Yes |
| EU Directive 2011/65/EU (RoHS 2): |
Yes |
| EU Directive 2012/19/EU (WEEE): |
Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment): |
Yes |
| EU Directive Compliance: |
Yes |
| MII Order #39 (China RoHS): |
Yes |
Suitability
| Suitability – Indoor: |
Yes |
Flammability, LS0H, Toxicity Testing
| UL Flammability: |
UL1666 Vertical Shaft |
| UL voltage rating: |
300 V RMS |
Plenum/Non-Plenum
Related Part Numbers
| Item # |
Color |
UPC |
| 502PTZ 0001000 |
Black, Blue, White |
612825155850 |
| 502PTZ 000500 |
Black, Blue, White |
612825155867 |
| Patent: |
This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
Product Notes
| Notes: |
RG59 CCTV + 1 STP18 AWG Control Grade + 2C 18 AWG CMR. Individually jacketed and color coded components, cabled around and each fused to a central binding spline. Cold environment installation: When installing cables that have been stored at ambient temperatures of 32 degrees Fahrenheit (0 degrees Centigrade) or lower, Belden recommends conditioning of the cable for 12 hours at room temperature prior to individual cable leg separation. |
History
| Update and Revision: |
Revision Number: 0.358 Revision Date: 05-05-2023 |