Description
Product Overview
Suitable Applications: | Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, …),low voltage digital control (24v, ), encoders, control circuits, distributed control system (DCS), programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners |
Construction Details
Conductor
Element | Size | Stranding | Material |
---|---|---|---|
Pair(s) | 14 AWG | 7×22 | BC – Bare Copper |
Insulation
Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|
PVC – Polyvinyl Chloride | 0.022 in (0.56 mm) | 0.114 in (2.90 mm) | Black & White and Numbered 1, Black & White and Numbered 2 |
Inner Shield
Shield Type | Material | Coverage |
---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% |
Outer Shield
Shield Type | Material | Coverage |
---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC – Polyvinyl Chloride | 0.053 in (1.3 mm) | 0.564 in (14.3 mm) |
Electrical Characteristics
Electricals
Nom. Conductor DCR | Nom. Inner Shield DCR | Max. Current |
---|---|---|
2.84 Ohm/1000ft | 0.96 Ohm/1000ft (3.1 Ohm/km) | 6.4 Amps per Conductor at 25ºC |
Voltage
UL Voltage Rating |
---|
300 V |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|---|
90°C | -30°C To +90°C |
Max. Pull Tension: | 218.4 lbs (99.06 kg) |
Bulk Cable Weight: | 138 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Outdoor, Sunlight Resistance, UV Resistance |
Sustainability: | CA Prop 65 |
Flammability / Reaction to Fire: | UL 1685 UL Loading, FT4, IEEE 1202 |
NEC / UL Compliance: | CMG, ITC, PLTC |
AWM Compliance: | AWM 2464 |
CEC / C(UL) Compliance: | CMG |
European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
History
Update and Revision: | Revision Number: 0.57 Revision Date: 01-04-2024 |