Welcome to American Tele Data

USA MADE - BABA COMPLIANT

AMERICAN TELEDATA

855 - 848 - Data

855 - 40 - Fiber

3084F – DeviceBus®, 2 Pr #22+24 Str TC, PVC+FPP Ins, IS+OA TC Brd, PVC Jkt, High Flex, CMG, CL2

Call for Price

Description

Product Overview

Suitable Applications: harsh environment, ODVA device-level communication, used with CIP (common Industrial Protocol) for control, configuration, and data collection between devices, such as sensors and actuators, and higher level devices such as PLC, and PC in industrial automation, bus topology, etc.

Construction Details

Conductor
Element No. of Elements Size Stranding Material
Power Pair(s) 1 22 AWG 154×44 TC – Tinned Copper
Data Pair(s) 1 24 AWG 105×44 TC – Tinned Copper
Insulation
Element Material Nom. Thickness Color Code
Power Pair(s) PVC – Polyvinyl Chloride 0.016 in (0.41 mm) Red & Black
Data Pair(s) PP – Polypropylene 0.026 in (0.66 mm) Blue & White
Inner Shield
Element Shield Type Material Coverage
Power Pair(s) Tape Bi-Laminate (Alum+Poly) 100%
Data Pair(s) Tape Bi-Laminate (Alum+Poly) 100%
Outer Shield
Shield Type Material Coverage Drainwire Type
Braid Tinned Copper (TC) 65% 22 AWG (26×36) TC
Outer Jacket
Material Nom. Thickness Nom. Diameter
PVC – Polyvinyl Chloride 0.036 in (0.91 mm) 0.275 in (6.99 mm)
Overall Cable Diameter (Nominal): 0.275 in (6.99 mm)

Electrical Characteristics

Electricals
Element Nom. Conductor DCR Max. Conductor DCR Nom. Capacitance Cond-to-Cond Nom. Characteristic Impedence Nom. Velocity of Prop. Max. Current
Power Pair(s) 17.5 Ohm/1000ft (57.4 Ohm/km) 17.5 Ohm/1000ft (57.4 Ohm/km) 4 Amps Per Conductor at 24 V (per NEC CL2) (Power Pair)
Data Pair(s) 28 Ohm/100m 12.0 pF/ft (39.4 pF/m) 120 Ohm 75% 4 Amps Per Conductor at 24 V (per NEC CL2) (Power Pair)
Nom. Outer Shield DCR: 3.2 Ohm/1000ft (10 Ohm/km)
High Frequency
Element Frequency [MHz] Max. Insertion Loss (Attenuation)
Data Pair(s) 0.125 .95 dB/100ft
0.5 1.64 dB/100ft
1 2.3 dB/100ft
Voltage
UL Voltage Rating
300 V (CMG)

Mechanical Characteristics

Temperature
UL Temperature Operating
75°C -20°C to +75°C
Bend Radius
Stationary Min. Installation Min.
2.75 in (69.9 mm) 2.75 in
Max. Pull Tension: 65 lbs (29 kg)
Bulk Cable Weight: 41 lbs/1000ft (61 kg/km)

Standards and Compliance

Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, Oil Resistance
Flammability / Reaction to Fire: UL1685 FT4 Loading, 1202
CPR Compliance: CPR Euroclass: Eca
NEC / UL Compliance: Article 725, Article 800, CL2, CMG
AWM Compliance: I/II A
CEC / C(UL) Compliance: CMG
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation Compliance: UKCA Mark
APAC Compliance: China RoHS II (GB/T 26572-2011)
Other Standard Compliance(s): ODVA Class 2 Thin

Product Notes

Notes: Hi-Flex. Thin. Flex Test Results: “S-Bend” Flex Test – 4″ Diameter Wheels, 2 lbs. tension: 150, 000 Cycles Averaged. +/-90 Degree Flex Test: 2″” Diameter, 2 lbs. tension – 8500 Cycles Averaged. Flex tests were conducted at less than the recommeded cable minimum bend radius. Actual cable performance will depend on the individual application. Meter marks on jacket to aid users in installation.

History

Update and Revision: Revision Number: 0.574 Revision Date: 12-22-2023

Part Numbers

Variants
Item # Color Putup Type Length UPC Footnote
3084F T5U500 Gray T5U Reel 500 ft 612825140955 C N
3084F T5U1000 Gray T5U Reel 1,000 ft 612825140931 C
3084F T5U2000 Gray T5U Reel 2,000 ft 612825140948 C
3084F T5U5000 Gray T5U Reel 5,000 ft 612825140962 C Z