Welcome to American Tele Data

USA MADE - BABA COMPLIANT

AMERICAN TELEDATA

855 - 848 - Data

855 - 40 - Fiber

3082A – DeviceBus®, 2 Pr #15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, CMG PLTC-ER

Call for Price

Description

Product Overview

Suitable Applications: harsh environment, ODVA device-level communication, used with CIP (common Industrial Protocol) for control, configuration, and data collection between devices, such as sensors and actuators, and higher level devices such as PLC, and PC in industrial automation, bus topology, etc.

Construction Details

Conductor
Element No. of Elements Size Stranding Material
Power Pair(s) 1 15 AWG 19×27 TC – Tinned Copper
Data Pair(s) 1 18 AWG 19×30 TC – Tinned Copper
Insulation
Element Material Nom. Thickness Nom. Insulation Diameter Color Code Notes
Power Pair(s) PVC – Polyvinyl Chloride 0.021 in (0.53 mm) 0.109 in (2.77 mm) Red & Black
Data Pair(s) PE – Polyethylene (Foam) 0.053 in (1.3 mm) 0.150 in (3.81 mm) Blue & White HDPE
Inner Shield
Element Shield Type Material Coverage
Power Pair(s) Tape Bi-Laminate (Alum+Poly) 100%
Data Pair(s) Tape Bi-Laminate (Alum+Poly) 100%
Outer Shield
Shield Type Material Coverage Drainwire Type
Braid Tinned Copper (TC) 65% 18 AWG (19×30) TC
Outer Jacket
Material Nom. Thickness Nom. Diameter
PVC – Polyvinyl Chloride 0.060 in (1.5 mm) 0.480 in (12.2 mm)
Table Notes: Jacket OD +/- 0.010
Overall Cable Diameter (Nominal): 0.480 in (12.2 mm)

Electrical Characteristics

Electricals
Element Nom. Conductor DCR Nom. Inner Shield DCR Nom. Capacitance Cond-to-Cond Nom. Characteristic Impedence Nom. Velocity of Prop. Max. Current
Power Pair(s) 3.58 Ohm/1000ft 5.75 Ohm/1000ft (18.9 Ohm/km) 16 Amps per Conductor at 30ºC
Data Pair(s) 7.2 Ohm/1000ft (24 Ohm/km) 3.58 Ohm/1000ft (11.7 Ohm/km) 12 pF/ft (39 pF/m) 120 Ohm 75% 14 Amps per Conductor at 30ºC
Nom. Outer Shield DCR: 7.29 Ohm/1000ft (23.9 Ohm/km)
High Frequency
Element Frequency [MHz] Max. Insertion Loss (Attenuation) Max./Min. Input Impedance (unFitted) [Ohm]
Data Pair(s) 0.125 0.13 dB/100ft 120
0.5 0.25 dB/100ft
1 0.36 dB/100ft
Voltage
UL Voltage Rating Voltage Rating
300 V (CMG, PLTC-ER), 600 V (AWM 20201) 300 V (AWM I/II A)

Mechanical Characteristics

Temperature
UL Temperature Operating
60°C -20°C to +60°C
Bend Radius
Stationary Min. Installation Min.
5.76 in (146 mm) 5.76 in (146 mm)
Max. Pull Tension: 192.6 lbs (87.36 kg)
Bulk Cable Weight: 128 lbs/1000ft

Standards and Compliance

Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, Oil Resistance
Flammability / Reaction to Fire: UL 1685 FT4 Loading, IEEE 1202 FT4, IEC 60332-1-2
CPR Compliance: CPR Euroclass: Eca
NEC / UL Compliance: Article 725, Article 800, CMG, PLTC
AWM Compliance: AWM 20201, AWM I/II A
CEC / C(UL) Compliance: CMG
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation Compliance: UKCA Mark
APAC Compliance: China RoHS II (GB/T 26572-2011)
Other Standard Compliance(s): ODVA Class 2 Thick

Product Notes

Notes: Thick. Meter marks on jacket to aid users in installation. ODVA DeviceNet is an Open DeviceNet Vendor Associatio, Inc. Trademark. Jacket printed “”1PR16″” instead of “”1PR15″” due to UL requirements for CMG Listing.

History

Update and Revision: Revision Number: 0.603 Revision Date: 12-22-2023

Part Numbers

Variants
Item # Color Putup Type Length UPC Footnote
3082A T5U500 Gray T5U Reel 500 ft 612825140788 C
3082A T5U2000 Gray T5U Reel 2,000 ft 612825140764 C
3082A T5U3000 Gray T5U Reel 3,000 ft 612825140771