Description
Product Overview
| Suitable Applications: | Variable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements |
Construction Details
Conductor
| Element | No. of Elements | Size | Stranding | Material |
|---|---|---|---|---|
| Conductor(s) | 3 | 12 AWG | 65×30 | TC – Tinned Copper |
| Ground Wire | 1 | 12 AWG | 65×30 | TC – Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Conductor(s) | XLPE – Cross-Linked Polyethylene (Thermoset) | 0.066 in (1.7 mm) | 0.225 in (5.72 mm) | ICEA Chart M4 |
| Ground Wire | XLPE – Cross-Linked Polyethylene (Thermoset) | 0.066 in (1.7 mm) | 0.225 in (5.72 mm) | Green/Yellow Stripe |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Tri-Laminate (Alum+Poly+Alum) | 100% | 12 AWG (65×30) TC |
| Braid | Tinned Copper (TC) | 85% |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | Ripcord |
|---|---|---|---|
| PVC – Polyvinyl Chloride | 0.073 in (1.9 mm) | 0.723 in (18.4 mm) | Yes |
| Overall Cable Diameter (Nominal): | 0.723 in (18.4 mm) |
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|---|---|---|---|---|---|
| Conductor(s) | 1.569 Ohm/1000ft | 54 pF/ft (180 pF/m) | 97 pF/ft (320 pF/m) | 44 Ohm | 55% | 30 Amps per Conductor at 30ºC |
| 1.72 Ohm/1000ft (5.64 Ohm/km) | 30 Amps per Conductor at 30ºC |
Voltage
| UL Voltage Rating |
|---|
| 2000 V (TC, C(UL) TC), 1000 V (WTTC, UL Flexible Motor Supply Cable, CSA AWM I/II A/B) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|---|
| 90°C Dry, 90°C Wet | -40°C To +90°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 8.7 in (220 mm) | 8.7 in (220 mm) |
| Max. Pull Tension: | 7922 lbs (3593 kg) |
| Bulk Cable Weight: | 336 lbs/1000ft |
Standards and Compliance
| Environmental Suitability: | Indoor, Outdoor, Sunlight Resistance, Burial |
| Sustainability: | CA Prop 65 |
| Flammability / Reaction to Fire: | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
| NEC / UL Compliance: | Article 336, TC-ER, WTTC, UL Flexible Motor Supply Cable |
| AWM Compliance: | AWM I/II A/B |
| ICEA Compliance: | S-95-658 |
| European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance: | China RoHS II (GB/T 26572-2011) |
| Other Standard Compliance(s): | P-07-KA070003-MSHA |
History
| Update and Revision: | Revision Number: 0.537 Revision Date: 12-22-2023 |
Part Numbers
Variants
| Item # | Color | Putup Type | Length | UPC |
|---|---|---|---|---|
| 29537 0101000 | Black | Reel | 1,000 ft | 612825138419 |
| 29537 0105000 | Black | Reel | 5,000 ft | 612825138426 |