Welcome to American Tele Data

USA MADE - BABA COMPLIANT

AMERICAN TELEDATA

855 - 848 - Data

855 - 40 - Fiber

29511 – VFD 300% Gnd, 3C+G #14 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd, 1 Pr #16 Str TC XLPE IS, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable

Call for Price

Description

Product Overview

Suitable Applications: Variable Frequency Drives (VFD); AC Motor and Drive Systems

Construction Details

Conductor
Element No. of Elements Size Stranding Material Notes
Conductor(s) 3 14 AWG 41×30 TC – Tinned Copper
Pair(s) 1 16 AWG 26×30 TC – Tinned Copper Used as control or brake pair
Ground Wire 1 14 AWG 41×30 TC – Tinned Copper
Insulation
Element Material Nom. Thickness Nom. Insulation Diameter Color Code
Conductor(s) XLPO – Crosslink Polyolefin 0.046 in (1.2 mm) 0.173 in (4.39 mm) ICEA Chart M4
Pair(s) XLPO – Crosslink Polyolefin 0.032 in (0.81 mm) 0.123 in (3.12 mm) Black & White
Ground Wire PVC – Polyvinyl Chloride 0.047 in (1.2 mm) 0.169 in (4.29 mm) Green/Yellow Stripe
Inner Shield
Element Shield Type Material Coverage Drainwire Type Notes
Pair(s) Tape Bi-Laminate (Alum+Poly) 100% 18 AWG (19×30) TC Foil-In, Shorting fold
Outer Shield
Shield Type Material Coverage Drainwire Type
Tape Tri-Laminate (Alum+Poly+Alum) 100% 14 AWG (41×30) TC
Braid Tinned Copper (TC) 85%
Table Notes: Foil+braid shield on power conductors & Ground only; extra pair has own foil shield.
Outer Jacket
Material Nom. Thickness Nom. Diameter Ripcord
PVC – Polyvinyl Chloride 0.075 in (1.9 mm) 0.820 in (20.8 mm) Yes
Overall Cable Diameter (Nominal): 0.820 in (20.8 mm)

Electrical Characteristics

Electricals
Element Nom. Conductor DCR Nom. Inner Shield DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Shield Nom. Capacitance Cond-to-Other (Conds + Shield) Nom. Characteristic Impedence Nom. Velocity of Prop. Max. Current
Conductor(s) 2.482 Ohm/1000ft 48 pF/ft (160 pF/m) 42 pF/ft (140 pF/m) 86 pF/ft (280 pF/m) 37 Ohm 55% 20 Amps per Conductor at 30ºC
Pair(s) 4.0 Ohm/1000ft (13 Ohm/km) 4.99 Ohm/1000ft (16.4 Ohm/km) 34 pF/ft (110 pF/m) 25 Amps per Conductor at 30ºC (per NEC)
Ground 2.52 Ohm/1000ft (8.27 Ohm/km) 23 pF/ft (75 pF/m) 42 pF/ft (140 pF/m) 25 Amps per Conductor at 30ºC (per NEC)
Voltage
UL Voltage Rating Voltage Rating
1000 V (UL Flexible Motor Supply Cable), 600 V (TC, C(UL) TC) 1000 V (AWM I/II A/B)

Mechanical Characteristics

Temperature
UL Temperature Operating
90°C Dry, 90°C Wet -40°C To +90°C
Bend Radius
Stationary Min. Installation Min.
9.8 in (250 mm) 9.8 in (250 mm)
Max. Pull Tension: 441 lbs (200 kg)
Bulk Cable Weight: 275 lbs/1000ft

Standards and Compliance

Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, Burial
Sustainability: CA Prop 65
Flammability / Reaction to Fire: UL 1685 UL Loading, FT4, IEEE 1202 FT4
NEC / UL Compliance: Article 336, Article 310, TC-ER, RHW-2, UL Flexible Motor Supply Cable
AWM Compliance: AWM I/II A/B
CEC / C(UL) Compliance: CIC, TC
ICEA Compliance: S-95-658
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC Compliance: China RoHS II (GB/T 26572-2011)
Other Standard Compliance(s): P-07-KA070003-MSHA

History

Update and Revision: Revision Number: 0.563 Revision Date: 12-22-2023

Part Numbers

Variants
Item # Color Putup Type Length UPC Footnote
29511 010100 Black Reel 100 ft 612825137481 C
29511 010500 Black Reel 500 ft 612825137504 C
29511 0101000 Black Reel 1,000 ft 612825137498 C
29511 0105000 Black Reel 5,000 ft 612825137511 C
You were not leaving your cart just like that, right?

You were not leaving your cart just like that, right?

Enter your details below to save your shopping cart for later. And, who knows, maybe we will even send you a sweet discount code :)