Description
Product Overview
| Suitable Applications: | Variable Frequency Drives (VFD); AC Motor and Drive Systems |
Construction Details
Conductor
| Element | No. of Elements | Size | Stranding | Material | Notes |
|---|---|---|---|---|---|
| Conductor(s) | 3 | 14 AWG | 41×30 | TC – Tinned Copper | |
| Pair(s) | 1 | 16 AWG | 26×30 | TC – Tinned Copper | Used as control or brake pair |
| Ground Wire | 1 | 14 AWG | 41×30 | TC – Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Conductor(s) | XLPO – Crosslink Polyolefin | 0.046 in (1.2 mm) | 0.173 in (4.39 mm) | ICEA Chart M4 |
| Pair(s) | XLPO – Crosslink Polyolefin | 0.032 in (0.81 mm) | 0.123 in (3.12 mm) | Black & White |
| Ground Wire | PVC – Polyvinyl Chloride | 0.047 in (1.2 mm) | 0.169 in (4.29 mm) | Green/Yellow Stripe |
Inner Shield
| Element | Shield Type | Material | Coverage | Drainwire Type | Notes |
|---|---|---|---|---|---|
| Pair(s) | Tape | Bi-Laminate (Alum+Poly) | 100% | 18 AWG (19×30) TC | Foil-In, Shorting fold |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Tri-Laminate (Alum+Poly+Alum) | 100% | 14 AWG (41×30) TC |
| Braid | Tinned Copper (TC) | 85% |
| Table Notes: | Foil+braid shield on power conductors & Ground only; extra pair has own foil shield. |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | Ripcord |
|---|---|---|---|
| PVC – Polyvinyl Chloride | 0.075 in (1.9 mm) | 0.820 in (20.8 mm) | Yes |
| Overall Cable Diameter (Nominal): | 0.820 in (20.8 mm) |
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Inner Shield DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Shield | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|---|---|---|---|---|---|---|---|
| Conductor(s) | 2.482 Ohm/1000ft | 48 pF/ft (160 pF/m) | 42 pF/ft (140 pF/m) | 86 pF/ft (280 pF/m) | 37 Ohm | 55% | 20 Amps per Conductor at 30ºC | |
| Pair(s) | 4.0 Ohm/1000ft (13 Ohm/km) | 4.99 Ohm/1000ft (16.4 Ohm/km) | 34 pF/ft (110 pF/m) | 25 Amps per Conductor at 30ºC (per NEC) | ||||
| Ground | 2.52 Ohm/1000ft (8.27 Ohm/km) | 23 pF/ft (75 pF/m) | 42 pF/ft (140 pF/m) | 25 Amps per Conductor at 30ºC (per NEC) |
Voltage
| UL Voltage Rating | Voltage Rating |
|---|---|
| 1000 V (UL Flexible Motor Supply Cable), 600 V (TC, C(UL) TC) | 1000 V (AWM I/II A/B) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|---|
| 90°C Dry, 90°C Wet | -40°C To +90°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 9.8 in (250 mm) | 9.8 in (250 mm) |
| Max. Pull Tension: | 441 lbs (200 kg) |
| Bulk Cable Weight: | 275 lbs/1000ft |
Standards and Compliance
| Environmental Suitability: | Indoor, Outdoor, Sunlight Resistance, Burial |
| Sustainability: | CA Prop 65 |
| Flammability / Reaction to Fire: | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
| NEC / UL Compliance: | Article 336, Article 310, TC-ER, RHW-2, UL Flexible Motor Supply Cable |
| AWM Compliance: | AWM I/II A/B |
| CEC / C(UL) Compliance: | CIC, TC |
| ICEA Compliance: | S-95-658 |
| European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance: | China RoHS II (GB/T 26572-2011) |
| Other Standard Compliance(s): | P-07-KA070003-MSHA |
History
| Update and Revision: | Revision Number: 0.563 Revision Date: 12-22-2023 |
Part Numbers
Variants
| Item # | Color | Putup Type | Length | UPC | Footnote |
|---|---|---|---|---|---|
| 29511 010100 | Black | Reel | 100 ft | 612825137481 | C |
| 29511 010500 | Black | Reel | 500 ft | 612825137504 | C |
| 29511 0101000 | Black | Reel | 1,000 ft | 612825137498 | C |
| 29511 0105000 | Black | Reel | 5,000 ft | 612825137511 | C |