Description
Product Overview
| Suitable Applications: | Variable Frequency Drives (VFD); AC Motor and Drive Systems, Exposure to high flex, motion, and abrasion, Hard to reach installation areas |
Construction Details
Conductor
| Element | No. of Elements | Size | Stranding | Material |
|---|---|---|---|---|
| Conductor(s) | 3 | 14 AWG | 104×34 | TC – Tinned Copper |
| Ground Wire | 1 | 14 AWG | 104×34 | TC – Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Conductor(s) | XLPO – Crosslink Polyolefin | 0.046 in (1.2 mm) | 0.167 in (4.24 mm) | ICEA Chart M4 |
| Ground Wire | PVC – Polyvinyl Chloride | 0.046 in (1.2 mm) | 0.167 in (4.24 mm) | Green/Yellow Stripe |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Tri-Laminate (Alum+Poly+Alum) | 100% | 14 AWG (104×34) TC |
| Braid | Tinned Copper (TC) | 86% |
Outer Jacket
| Separator | Material | Nom. Thickness | Nom. Diameter | Ripcord |
|---|---|---|---|---|
| Polyester Tape | TPE – Thermoplastic Elastomer | 0.073 in (1.9 mm) | 0.587 in (14.9 mm) | Yes |
| Overall Cable Diameter (Nominal): | 0.587 in (14.9 mm) |
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|---|---|---|---|---|---|
| Conductor(s) | 2.468 Ohm/1000ft | 40 pF/ft (130 pF/m) | 72 pF/ft (240 pF/m) | 46 Ohm | 55% | 25 Amps per Conductor at 30ºC (per NEC) |
| 2.73 Ohm/1000ft (8.96 Ohm/km) | 25 Amps per Conductor at 30ºC (per NEC) |
Voltage
| UL Voltage Rating |
|---|
| 1000 V (TC-ER, XHHW-2, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|---|
| 90°C Dry, 90°C Wet | -40°C To +90°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 7.0 in (180 mm) | 7.0 in (180 mm) |
| Max. Pull Tension: | 340 lbs (150 kg) |
| Bulk Cable Weight: | 216 lbs/1000ft |
Standards and Compliance
| Environmental Suitability: | Indoor, Outdoor, Sunlight Resistance |
| Sustainability: | CA Prop 65 |
| Flammability / Reaction to Fire: | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
| NEC / UL Compliance: | Article 336, Article 310, TC-ER, XHHW-2, UL Flexible Motor Supply Cable |
| CEC / C(UL) Compliance: | CIC, TC |
| ICEA Compliance: | S-95-658 |
| European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance: | China RoHS II (GB/T 26572-2011) |
History
| Update and Revision: | Revision Number: 0.191 Revision Date: 12-22-2023 |
Part Numbers
Variants
| Item # | Color | Putup Type | Length | UPC |
|---|---|---|---|---|
| 29501F 0101000 | Black | Reel | 1,000 ft | 612825367222 |
| 29501F 0105000 | Black | Reel | 5,000 ft | 612825367253 |