Product Overview
Suitable Applications: |
harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc. |
Physical Characteristics (Overall)
Element |
AWG |
Stranding |
Material |
Nominal Diameter |
No. of Conductors |
Conductor(s) |
6 |
7×14.5 |
BC – Bare Copper |
0.179 in |
4 |
Material |
Nominal Diameter |
PVC/Nylon – Polyvinyl Chloride + Nylon |
0.254 in |
Number |
Color |
1 |
Black Numbered 1 |
2 |
Black Numbered 2 |
3 |
Black Numbered 3 |
4 |
Black Numbered 4 |
Material |
Nominal Diameter |
Nominal Wall Thickness |
PVC – Polyvinyl Chloride |
0.738 in |
0.063 in |
Electrical Characteristics
Nominal Conductor DCR |
0.41 Ohm/1000ft |
Max. Recommended Current [A] |
60 Amps per Conductor at 30ºC |
UL Description |
UL Voltage Rating |
Voltage Rating [V] |
TC-ER |
600 V RMS (Type TC) |
600 V RMS (Type TC) |
Temperature Range
UL Temp Rating: |
90°C Dry, 75°C Wet |
Operating Temperature Range: |
-25°C To +90°C |
Mechanical Characteristics
Min Bend Radius (Overall): |
7.38 in |
Min. Bend Radius/Minor Axis: |
2.95 in |
Standards
NEC/(UL) Compliance: |
TC-ER |
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2011/65/EU (RoHS 2): |
Yes |
EU Directive 2012/19/EU (WEEE): |
Yes |
EU Directive 2015/863/EU (RoHS 2 amendment): |
Yes |
EU Directive Compliance: |
EU Directive 2003/11/EC (BFR) |
Suitability
Suitability – Burial: |
Yes |
Suitability – Indoor: |
Yes |
Suitability – Outdoor: |
Yes |
Suitability – Sunlight Resistance: |
Yes |
Flammability, LS0H, Toxicity Testing
UL Flammability: |
UL1685 Vertical Tray Flame Test |
UL voltage rating: |
600 V RMS (Type TC) |
Related Part Numbers
Item # |
Put-Up Type |
28154AX 0105000 |
Reel |
History
Update and Revision: |
Revision Number: 0.117 Revision Date: 01-10-2024 |