Product Overview
| Suitable Applications: |
Analog audio, burial, Sports Stadium |
Physical Characteristics (Overall)
| AWG |
Stranding |
Material |
Nominal Diameter |
No. of Pairs |
| 22 |
7×30 |
TC – Tinned Copper |
0.029 in |
2 |
| Material |
Nominal Diameter |
| PP – Polypropylene |
0.05 in |
| Number |
Color |
| 1 |
Red & Black |
| Type |
Material |
Material Trade Name |
Coverage [%] |
Drainwire Material |
Drainwire AWG |
| Tape |
Bi-Laminate (Alum+Poly) |
Beldfoil® |
100% |
TC – Tinned Copper |
22 |
| Material |
Nominal Diameter |
| PVC – Polyvinyl Chloride |
0.133 in |
| Type |
Material |
Material Trade Name |
Coverage [%] |
Drainwire Material |
Drainwire AWG |
| Tape |
Bi-Laminate (Alum+Poly) |
Beldfoil® |
100% |
TC – Tinned Copper |
22 |
| Material |
Nominal Diameter |
| CPE – Chlorinated Polyethylene |
0.358 in |
Electrical Characteristics
| Individual Pair Nominal Shield DCR |
Nominal Conductor DCR |
Nominal Outer Shield DCR |
| 14.1 Ohm/1000ft |
14.8 Ohm/1000ft |
11.8 Ohm/1000ft |
| Nom. Capacitance Conductor to Conductor |
Nom. Capacitance Conductor to Other Conductor to Shield |
| 31 pF/ft |
56 pF/ft |
| Nominal Inductance |
| 0.18 µH/ft |
| Nominal Characteristic Impedance |
| 50 Ohm |
| Nominal Velocity of Propagation (VP) [%] |
| 66% |
| Max. Recommended Current [A] |
| 1.45 Amps per Conductor at 25ºC |
| UL Voltage Rating |
| 300 V RMS |
Temperature Range
| Operating Temperature Range: |
-20°C To +75°C |
Mechanical Characteristics
| Bulk Cable Weight: |
57 lbs/1000ft |
| Max. Pull Tension: |
64 lbs |
| Min. Bend Radius/Minor Axis: |
3.6 in |
Standards
Applicable Environmental and Other Programs
| Environmental Space: |
Indoor/Outdoor |
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2003/96/EC (BFR): |
Yes |
| EU Directive 2011/65/EU (RoHS 2): |
Yes |
| EU Directive 2012/19/EU (WEEE): |
Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment): |
Yes |
| EU Directive Compliance: |
EU Directive 2003/11/EC (BFR) |
Suitability
| Suitability – Aerial: |
Yes – When supported by messenger wire |
| Suitability – Hazardous Locations: |
No |
| Suitability – Indoor: |
Yes |
| Suitability – Outdoor: |
Yes |
Flammability, LS0H, Toxicity Testing
| UL Flammability: |
UL1666 Riser |
| UL voltage rating: |
300 V RMS |
Plenum/Non-Plenum
Related Part Numbers
| Item # |
Color |
Put-Up Type |
Length |
UPC |
| 2814RW 0101000 |
Black |
Reel |
1,000 ft |
612825384861 |
| 2814RW 0105000 |
Black |
Reel |
5,000 ft |
612825384878 |
| Footnote: |
C – CRATE REEL PUT-UP., Z – FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. |
Product Notes
| Notes: |
Water blocking tape between outer shield and outer jacket. Pair jackets and shields are bonded so both strip simultaneously with automatic stripping equipment. Beldfoil® provides high reliability with ease of termination. Print legend includes sequential footage marks. |
History
| Update and Revision: |
Revision Number: 0.323 Revision Date: 01-10-2024 |