28123AS – TC VN/PVC, 16 C #12 Str BC, PVC-NYL Ins E2, OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR

Call for Price

Compare

Description

Product Overview

Suitable Applications: harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Physical Characteristics (Overall)

Conductor
Element AWG Stranding Material Nominal Diameter No. of Conductors
Conductor(s) 12 7×20 BC – Bare Copper 0.089 in 16
Conductor Count: 16
Insulation
Material Nominal Diameter
PVC/Nylon – Polyvinyl Chloride + Nylon 0.121 in
Color Chart
Number Color
1 Black
2 Red
3 Blue
4 Orange
5 Yellow
6 Brown
7 Red/Black
8 Blue/Black
9 Orange/Black
10 Yellow/Black
11 Brown/Black
12 Black/Red
13 Blue/Red
14 Orange/Red
15 Yellow/Red
16 Brown/Red
Outer Shield
Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG
Tape Bi-Laminate (Alum+Poly) Beldfoil® 100% TC – Tinned Copper 12
Outer Jacket
Material Nominal Diameter Nominal Wall Thickness
PVC – Polyvinyl Chloride 0.740 in 0.063 in

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR
1.65 Ohm/1000ft
Current
Max. Recommended Current [A]
15 Amps per Conductor at 30ºC
Voltage
UL Description UL Voltage Rating Voltage Rating [V]
TC-ER 600 V RMS (Type TC) 600 V RMS (Type TC)

Temperature Range

UL Temp Rating: 90°C Dry, 90°C Wet
Operating Temperature Range: -25°C To +90°C
Wet Temp Range: -30°C To +90 °C
Dry Temp Range: -30°C To +90 °C

Mechanical Characteristics

UV Resistance: Yes
Min Bend Radius (Overall): 7.4 in

Standards

NEC/(UL) Compliance: NPLF, TC-ER

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: Yes

Suitability

Suitability – Burial: Yes
Suitability – Indoor: Yes
Suitability – Outdoor: Yes
Suitability – Sunlight Resistance: Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: UL1685 Vertical Tray Flame Test
IEEE Flammability: 1202
UL voltage rating: 600 V RMS (Type TC)

Related Part Numbers

Variants
Item # Put-Up Type
28123AS 0105000 Reel

History

Update and Revision: Revision Number: 0.51 Revision Date: 01-10-2024