27600A – TC VN/PVC, 6 C #18 Str BC, PVC-NYL Ins E2, Blk PVC Jkt, 600V TC 150V NPLF 90C Dry/Wet SUN RES DIR BUR

Call for Price

Compare

Description

Product Overview

Suitable Applications: Power and Control Applications up to 600V

Construction Details

Conductor
Element No. of Elements Size Stranding Material
Conductor(s) 6 18 AWG 7×26 BC – Bare Copper
Insulation
Element Material Nom. Thickness Nom. Insulation Diameter Color Code
Conductor(s) PVC/Nylon – Polyvinyl Chloride + Nylon 0.020 in (0.51 mm) 0.087 in (2.2 mm) ICEA Chart E2
Outer Shield
Material
No Shield
Outer Jacket
Material Nom. Thickness Nom. Diameter Ripcord
PVC – Polyvinyl Chloride 0.047 in (1.2 mm) 0.352 in Yes
Overall Cable Diameter (Nominal): 0.352 in

Electrical Characteristics

Electricals
Nom. Conductor DCR Max. Current
6.66 Ohm/1000ft 11.2 Amps per Conductor at 30ºC
Voltage
UL Voltage Rating
600 V (TC), 150 V (NPLF)

Mechanical Characteristics

Temperature
UL Temperature Operating
90°C Dry, 75°C Wet Wet/Dry: -30°C To 90°C
Bend Radius
Stationary Min. Installation Min.
1.408 in (35.76 mm) 1.76 in
Max. Pull Tension: 135 lbs (61.2 kg)
Bulk Cable Weight: 77 lbs/1000ft

Standards and Compliance

Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, UV Resistance, Burial
Flammability / Reaction to Fire: UL 1685 UL Loading, IEEE 1202 FT4
CPR Compliance: CPR Euroclass: Eca
NEC / UL Compliance: Article 336, NPLF, TC
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation Compliance: UKCA Mark
APAC Compliance: China RoHS II (GB/T 26572-2011)

History

Update and Revision: Revision Number: 0.422 Revision Date: 06-06-2023

Part Numbers

Variants
Item # Color Putup Type Length UPC Footnote
27600A 0105000 Black Reel 5,000 ft 612825134138 C Z
27600A 01010000 Black Reel 10,000 ft 612825134121 C Z